Included study
ESTRATÉGIA DE MANUTENÇÃO EM UMA USINA DE AÇUCAR E ALCOOL UTILIZANDO MODELO ESTATÍSTICO DE CONFIABILIDADE
1Bibliographic record
- Authors
- Timóteo Simão Ferreira, Jorge Alberto Achcar
- Year
- 2024
- Venue
- Anais do ... Simpósio de Engenharia de Produção
- Country
- Brazil
- Segment
- Sugar and confectionery
- Process family
- Slaughter, cutting and primary processing
- Study type
- Reliability analysis
- Extraction scope
- Full text
- Size
- 1 plants · — lines · 2 machines
- Observation period
- 1,825 days
- Data collection
- maintenance_records
- Intervention
Show the setting as described by the study
Este estudo é relacionado à manutenção de duas moendas em uma usina especializada na produção de açúcar, etanol e energia elétrica localizada no estado de São Paulo, Brasil.
2Risk of bias
Scored with the rubric of the protocol: 2 low concern, 1 some concerns, 0 high concern.
Total score 12Moderate risk
| Item | Score |
|---|---|
| Is the observed line, machine or plant described well enough to classify its segment, process and equipment?Product, process and equipment are all described. | 2 / 2 |
| Is the observation period long enough and reported?Period reported and at least 30 days of production (or at least 100 recorded events). | 2 / 2 |
| How were loss data collected?Manual logs or maintenance records with unknown completeness. | 1 / 2 |
| Are OEE, loading time and the loss categories defined explicitly?No definition; metrics are reported as bare numbers. | 0 / 2 |
| Does the loss breakdown account for the total loss it claims to explain?Only the top causes are reported and the unexplained remainder can be computed. | 1 / 2 |
| Is there evidence of selective reporting of favourable results?Observational study, or intervention study that reports baseline and post-intervention data with the same method. | 2 / 2 |
| Are the reported numbers internally consistent?Recomputed totals, shares and OEE factors agree with the reported values within 2 percentage points. | 2 / 2 |
| Could conflicts of interest or the source of the data bias the result?Academic or independent study, or conflicts declared and unrelated to the result. | 2 / 2 |
3Extracted data
Each datum with its classification and the verbatim quote that states it.
| Reported cause | Loss category | Metric | Value | Extraction |
|---|---|---|---|---|
—Show verbatim quote (Table 1)moenda A 697 100,53 173,06 29949,74 45,00 | Equipment failure (breakdowns) | Mean event duration | 101 min | Both extractors agreed |
—Show verbatim quote (Table 1)moenda B 713 93,06 159,81 25538,23 37,80 | Equipment failure (breakdowns) | Mean event duration | 93.1 min | Both extractors agreed |
—Show verbatim quote (Table 1)moenda B 713 93,06 159,81 25538,23 37,80 | Equipment failure (breakdowns) | Number of events | 713 events | Both extractors agreed |
—Show verbatim quote (Table 1)moenda A 697 100,53 173,06 29949,74 45,00 | Equipment failure (breakdowns) | Number of events | 697 events | Both extractors agreed |
Electrical Maintenance (ELET)Show verbatim quote (Table 3)ELET 97 61,9 108,5 11763,1 28,2 | Equipment failure (breakdowns) | Number of events | 97.0 events | Single extractor |
Electrical Maintenance (ELET)Show verbatim quote (Table 3)ELET 97 61,9 108,5 11763,1 28,2 | Equipment failure (breakdowns) | Mean event duration | 61.9 min | Single extractor |
Excess milling capacity / over-processing (EXCM)Show verbatim quote (Table 3)EXCM 23 142,3 205,8 42339,1 51,0 | Equipment failure (breakdowns) | Number of events | 23.0 events | Single extractor |
Excess milling capacity / over-processing (EXCM)Show verbatim quote (Table 3)EXCM 23 142,3 205,8 42339,1 51,0 | Equipment failure (breakdowns) | Mean event duration | 142 min | Single extractor |
Extraction and milling (EXTR)Show verbatim quote (Table 3)EXTR 250 91,24 137,80 18988,05 41,40 | Equipment failure (breakdowns) | Number of events | 250 events | Single extractor |
Extraction and milling (EXTR)Show verbatim quote (Table 3)EXTR 250 91,24 137,80 18988,05 41,40 | Equipment failure (breakdowns) | Mean event duration | 91.2 min | Single extractor |
Sugar factory (FABR)Show verbatim quote (Table 3)FABR 106 69,79 76,71 5885,13 49,80 | Equipment failure (breakdowns) | Number of events | 106 events | Single extractor |
Sugar factory (FABR)Show verbatim quote (Table 3)FABR 106 69,79 76,71 5885,13 49,80 | Equipment failure (breakdowns) | Mean event duration | 69.8 min | Single extractor |
Steam generation (GVAP)Show verbatim quote (Table 3)GVAP 53 119,1 150,3 22580,0 52,2 | Equipment failure (breakdowns) | Number of events | 53.0 events | Single extractor |
Steam generation (GVAP)Show verbatim quote (Table 3)GVAP 53 119,1 150,3 22580,0 52,2 | Equipment failure (breakdowns) | Mean event duration | 119 min | Single extractor |
Instrumentation (INST)Show verbatim quote (Table 3)INST 50 47,83 51,52 2653,99 30,00 | Equipment failure (breakdowns) | Number of events | 50.0 events | Single extractor |
Instrumentation (INST)Show verbatim quote (Table 3)INST 50 47,83 51,52 2653,99 30,00 | Equipment failure (breakdowns) | Mean event duration | 47.8 min | Single extractor |
Mechanical Maintenance (MECN)Show verbatim quote (Table 3)MECN 104 202,9 319,6 102155,8 74,4 | Equipment failure (breakdowns) | Number of events | 104 events | Single extractor |
Mechanical Maintenance (MECN)Show verbatim quote (Table 3)MECN 104 202,9 319,6 102155,8 74,4 | Equipment failure (breakdowns) | Mean event duration | 203 min | Single extractor |
Mill driveShow verbatim quote (Table 8)Acionamento da moenda 52 153,6 281,1 78992,4 50,4 | Equipment failure (breakdowns) | Number of events | 52.0 events | Single extractor |
Mill driveShow verbatim quote (Table 8)Acionamento da moenda 52 153,6 281,1 78992,4 50,4 | Equipment failure (breakdowns) | Mean event duration | 154 min | Single extractor |
System feedingShow verbatim quote (Table 8)Alimentação do sistema 36 146,1 221,5 49060,6 55,5 | Equipment failure (breakdowns) | Number of events | 36.0 events | Single extractor |
System feedingShow verbatim quote (Table 8)Alimentação do sistema 36 146,1 221,5 49060,6 55,5 | Equipment failure (breakdowns) | Mean event duration | 146 min | Single extractor |
Sugar storageShow verbatim quote (Table 8)Armazenagem de açúcar 5 97,6 94,6 8956,9 64,2 | Equipment failure (breakdowns) | Number of events | 5.00 events | Single extractor |
Sugar storageShow verbatim quote (Table 8)Armazenagem de açúcar 5 97,6 94,6 8956,9 64,2 | Equipment failure (breakdowns) | Mean event duration | 97.6 min | Single extractor |
ImbibitionShow verbatim quote (Table 8)Embebição 39 57,2 74,6 5567,1 39,0 | Equipment failure (breakdowns) | Number of events | 39.0 events | Single extractor |
ImbibitionShow verbatim quote (Table 8)Embebição 39 57,2 74,6 5567,1 39,0 | Equipment failure (breakdowns) | Mean event duration | 57.2 min | Single extractor |
Intermediate conveyorShow verbatim quote (Table 8)Esteira Intermediária 44 35,02 36,51 1332,87 22,50 | Equipment failure (breakdowns) | Number of events | 44.0 events | Single extractor |
Intermediate conveyorShow verbatim quote (Table 8)Esteira Intermediária 44 35,02 36,51 1332,87 22,50 | Equipment failure (breakdowns) | Mean event duration | 35.0 min | Single extractor |
Excess milling capacityShow verbatim quote (Table 8)Excesso Capacidade de Mo 3 198,0 270,0 72750,0 60,0 | Equipment failure (breakdowns) | Number of events | 3.00 events | Single extractor |
Excess milling capacityShow verbatim quote (Table 8)Excesso Capacidade de Mo 3 198,0 270,0 72750,0 60,0 | Equipment failure (breakdowns) | Mean event duration | 198 min | Single extractor |
Sugar manufacturingShow verbatim quote (Table 8)Fabricação de açúcar 78 92,9 150,0 22513,3 48,0 | Equipment failure (breakdowns) | Number of events | 78.0 events | Single extractor |
Sugar manufacturingShow verbatim quote (Table 8)Fabricação de açúcar 78 92,9 150,0 22513,3 48,0 | Equipment failure (breakdowns) | Mean event duration | 92.9 min | Single extractor |
Lack of cane - transportShow verbatim quote (Table 8)Falta de cana - transpor 1 52,800 * * 52,800 | Organizational or external stops (material or personnel shortage, utilities outage) | Number of events | 1.00 events | Single extractor |
Lack of cane - transportShow verbatim quote (Table 8)Falta de cana - transpor 1 52,800 * * 52,800 | Organizational or external stops (material or personnel shortage, utilities outage) | Mean event duration | 52.8 min | Single extractor |
Energy generationShow verbatim quote (Table 8)Geração de energia 20 108,8 111,9 12519,0 64,8 | Equipment failure (breakdowns) | Number of events | 20.0 events | Single extractor |
Energy generationShow verbatim quote (Table 8)Geração de energia 20 108,8 111,9 12519,0 64,8 | Equipment failure (breakdowns) | Mean event duration | 109 min | Single extractor |
Steam generationShow verbatim quote (Table 8)Geraçao de vapor 41 93,1 116,1 13480,3 45,0 | Equipment failure (breakdowns) | Number of events | 41.0 events | Single extractor |
Steam generationShow verbatim quote (Table 8)Geraçao de vapor 41 93,1 116,1 13480,3 45,0 | Equipment failure (breakdowns) | Mean event duration | 93.1 min | Single extractor |
Bagasse handlingShow verbatim quote (Table 8)Movimentação de bagaço 71 88,8 126,8 16084,5 33,0 | Equipment failure (breakdowns) | Number of events | 71.0 events | Single extractor |
Bagasse handlingShow verbatim quote (Table 8)Movimentação de bagaço 71 88,8 126,8 16084,5 33,0 | Equipment failure (breakdowns) | Mean event duration | 88.8 min | Single extractor |
OtherShow verbatim quote (Table 8)outro 1 25,200 * * 25,200 | Not classifiable from the report | Number of events | 1.00 events | Single extractor |
OtherShow verbatim quote (Table 8)outro 1 25,200 * * 25,200 | Not classifiable from the report | Mean event duration | 25.2 min | Single extractor |
Cane preparationShow verbatim quote (Table 8)Preparo de cana 135 138,3 246,5 60760,6 51,0 | Equipment failure (breakdowns) | Number of events | 135 events | Single extractor |
Cane preparationShow verbatim quote (Table 8)Preparo de cana 135 138,3 246,5 60760,6 51,0 | Equipment failure (breakdowns) | Mean event duration | 138 min | Single extractor |
Milling rampShow verbatim quote (Table 8)Rampa de Moagem 24 150,4 205,1 42061,1 53,4 | Equipment failure (breakdowns) | Number of events | 24.0 events | Single extractor |
Milling rampShow verbatim quote (Table 8)Rampa de Moagem 24 150,4 205,1 42061,1 53,4 | Equipment failure (breakdowns) | Mean event duration | 150 min | Single extractor |
Cane receptionShow verbatim quote (Table 8)Recepção de cana 15 40,7 64,6 4177,7 15,0 | Equipment failure (breakdowns) | Number of events | 15.0 events | Single extractor |
Cane receptionShow verbatim quote (Table 8)Recepção de cana 15 40,7 64,6 4177,7 15,0 | Equipment failure (breakdowns) | Mean event duration | 40.7 min | Single extractor |
Mill trainShow verbatim quote (Table 8)Terno de moenda 36 72,8 78,0 6080,9 41,4 | Equipment failure (breakdowns) | Number of events | 36.0 events | Single extractor |
Mill trainShow verbatim quote (Table 8)Terno de moenda 36 72,8 78,0 6080,9 41,4 | Equipment failure (breakdowns) | Mean event duration | 72.8 min | Single extractor |
Juice treatmentShow verbatim quote (Table 8)Tratamento de caldo 91 70,71 86,06 7405,94 45,00 | Equipment failure (breakdowns) | Number of events | 91.0 events | Single extractor |
Juice treatmentShow verbatim quote (Table 8)Tratamento de caldo 91 70,71 86,06 7405,94 45,00 | Equipment failure (breakdowns) | Mean event duration | 70.7 min | Single extractor |
UtilitiesShow verbatim quote (Table 8)Utilidades 5 79,8 50,5 2547,5 82,2 | Organizational or external stops (material or personnel shortage, utilities outage) | Number of events | 5.00 events | Single extractor |
UtilitiesShow verbatim quote (Table 8)Utilidades 5 79,8 50,5 2547,5 82,2 | Organizational or external stops (material or personnel shortage, utilities outage) | Mean event duration | 79.8 min | Single extractor |
ELETShow verbatim quote (Table 3 - Estatísticas descritivas associadas aos níveis do fator causa)ELET 97 61,9 108,5 11763,1 28,2 | Equipment failure (breakdowns) | Number of events | 97.0 events | Single extractor |
ELETShow verbatim quote (Table 3 - Estatísticas descritivas associadas aos níveis do fator causa)ELET 97 61,9 108,5 11763,1 28,2 | Equipment failure (breakdowns) | Mean event duration | 61.9 min | Single extractor |
EXCMShow verbatim quote (Table 3 - Estatísticas descritivas associadas aos níveis do fator causa)EXCM 23 142,3 205,8 42339,1 51,0 | Organizational or external stops (material or personnel shortage, utilities outage) | Number of events | 23.0 events | Single extractor |
EXCMShow verbatim quote (Table 3 - Estatísticas descritivas associadas aos níveis do fator causa)EXCM 23 142,3 205,8 42339,1 51,0 | Organizational or external stops (material or personnel shortage, utilities outage) | Mean event duration | 142 min | Single extractor |
EXTRShow verbatim quote (Table 3 - Estatísticas descritivas associadas aos níveis do fator causa)EXTR 250 91,24 137,80 18988,05 41,40 | Equipment failure (breakdowns) | Number of events | 250 events | Single extractor |
EXTRShow verbatim quote (Table 3 - Estatísticas descritivas associadas aos níveis do fator causa)EXTR 250 91,24 137,80 18988,05 41,40 | Equipment failure (breakdowns) | Mean event duration | 91.2 min | Single extractor |
FABRShow verbatim quote (Table 3 - Estatísticas descritivas associadas aos níveis do fator causa)FABR 106 69,79 76,71 5885,13 49,80 | Equipment failure (breakdowns) | Number of events | 106 events | Single extractor |
FABRShow verbatim quote (Table 3 - Estatísticas descritivas associadas aos níveis do fator causa)FABR 106 69,79 76,71 5885,13 49,80 | Equipment failure (breakdowns) | Mean event duration | 69.8 min | Single extractor |
GVAPShow verbatim quote (Table 3 - Estatísticas descritivas associadas aos níveis do fator causa)GVAP 53 119,1 150,3 22580,0 52,2 | Equipment failure (breakdowns) | Number of events | 53.0 events | Single extractor |
GVAPShow verbatim quote (Table 3 - Estatísticas descritivas associadas aos níveis do fator causa)GVAP 53 119,1 150,3 22580,0 52,2 | Equipment failure (breakdowns) | Mean event duration | 119 min | Single extractor |
INSTShow verbatim quote (Table 3 - Estatísticas descritivas associadas aos níveis do fator causa)INST 50 47,83 51,52 2653,99 30,00 | Equipment failure (breakdowns) | Number of events | 50.0 events | Single extractor |
INSTShow verbatim quote (Table 3 - Estatísticas descritivas associadas aos níveis do fator causa)INST 50 47,83 51,52 2653,99 30,00 | Equipment failure (breakdowns) | Mean event duration | 47.8 min | Single extractor |
MECNShow verbatim quote (Table 3 - Estatísticas descritivas associadas aos níveis do fator causa)MECN 104 202,9 319,6 102155,8 74,4 | Equipment failure (breakdowns) | Number of events | 104 events | Single extractor |
MECNShow verbatim quote (Table 3 - Estatísticas descritivas associadas aos níveis do fator causa)MECN 104 202,9 319,6 102155,8 74,4 | Equipment failure (breakdowns) | Mean event duration | 203 min | Single extractor |
Observation units
- Moenda A · Milling and grinding · Baseline