foratvise
Get Started
Equipment failure (breakdowns)

Fastener or bolt breakage

Equipment failure (breakdowns)AvailabilityFilling

In short

It appears in about 1 of every 100 lines studied.

When it appears, it takes on average about 56 % of the line's lost time. Reported by 1 of the 120 studies that could observe it (sparse evidence).

What happens

Bolts, screws or other fasteners holding filling-station components in place fatigue, loosen or are overloaded by vibration and cyclic mechanical stress until they shear or snap completely. Once a fastener fails, the attached part can become loose or detach, causing misalignment, collisions or complete breakage of the component it secured.

What is done about it

Apply preventive maintenance with scheduled inspection and torque verification of critical fasteners, use locking washers, thread-locking compounds or self-locking nuts on vibration-prone joints, and select fastener grade and material appropriate to the mechanical loads involved. Vibration monitoring and periodic visual inspection help detect loosening before a fastener breaks completely.

Practical guidance written from engineering knowledge; it is not a statistical estimate.

1Probability and evidence

Pooled over all segments. A wide interval is a result: it states how much the evidence allows us to know.
Probability of presence
0.6% [0.1–1.6%]
Expected share of lost time
0.3% [0.1–0.9%]
Share of lost time when present
56% [45–66%]
Studies / units
120 / 162
Evidence grade
D

Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.

2Probability by segment

Partially pooled estimates for each industry segment.
  • Dairy products
    0.9% [0.1–3.2%]18 studies
  • Soft drinks, bottled water and juices
    0.5% [0.1–1.8%]44 studies
  • Brewing, wine and spirits
    0.6% [0.1–2.3%]16 studies
  • Bakery and pasta
    0.7% [0.1–2.7%]0 studies
  • Meat, poultry and seafood
    0.7% [0.1–2.5%]6 studies
  • Fruit and vegetable processing
    0.7% [0.1–2.7%]4 studies
  • Grain and oilseed milling
    0.7% [0.1–2.6%]6 studies
  • Sugar and confectionery
    0.7% [0.1–2.6%]3 studies
  • Snacks, coffee, tea and other foods
    0.7% [0.1–2.5%]6 studies
  • Animal feed and pet food
    0.7% [0.1–2.5%]4 studies
  • Food manufacturing (unspecified or mixed)
    0.7% [0.1–2.5%]13 studies

3Mechanism, SCADA signature and countermeasure

Engineering guidance that helps recognise and address the cause; it is not part of the statistical estimate.

Mechanism

Engineering guidance

Bolts, screws or other fasteners holding filling-station components in place fatigue, loosen or are overloaded by vibration and cyclic mechanical stress until they shear or snap completely. Once a fastener fails, the attached part can become loose or detach, causing misalignment, collisions or complete breakage of the component it secured.

How it looks in SCADA data

Engineering guidance

SCADA/MES logs show an unplanned stop with a mechanical fault or safety-interlock alarm at the filling machine, often preceded by rising vibration or torque readings on the affected axis. The machine state transitions abruptly to fault/down with a maintenance work order code, and no gradual speed degradation is seen beforehand, distinguishing it from wear-related slow failures.

Countermeasure

Engineering guidance

Apply preventive maintenance with scheduled inspection and torque verification of critical fasteners, use locking washers, thread-locking compounds or self-locking nuts on vibration-prone joints, and select fastener grade and material appropriate to the mechanical loads involved. Vibration monitoring and periodic visual inspection help detect loosening before a fastener breaks completely.

4Sources

Every extracted datum with its study, value and verbatim quote.
  1. Time between events: 19,964 not reported · as reported: “Baut Penopang Washing Fork”
    Show verbatim quote
    Waktu Kerusakan Weibull MTTF 19963,56
  2. Mean event duration: 146 not reported · as reported: “Baut Penopang Washing Fork”
    Show verbatim quote
    Waktu Perbaikan Weibull MTTR 145,769
  3. Number of events: 4,518 cases · as reported: “Full breakage”
    Show verbatim quote
    Full breakage and out-of-space defects were less common, contributing 4,518 and 1,296 cases, respectively, across the study period.
  4. Lost time: 8.50 h · as reported: “Bolt/fastener breakage”
    Show verbatim quote
    Rotura de pernería 8,50 74%