Fill content or contamination defect
In short
It appears in about 1 of every 100 lines studied.
When it appears, it takes on average about 48 % of the line's lost time. Reported by 2 of the 120 studies that could observe it (limited evidence).
What happens
Variability in the dosing or filling valve, flow meter drift, or changes in product viscosity and temperature cause the delivered volume or weight of product (for example oil content) to fall below specification. Separately, ingress of foreign matter, residual cleaning or sanitising agents, or microbial contamination during the filling step renders units unfit for use even when the fill level itself is correct.
What is done about it
Calibrate and periodically verify dosing valves, pumps and flow meters against reference standards, and compensate for product viscosity and temperature in the filling control logic. Reinforce cleaning and sanitation validation, use foreign-particle or seal-integrity detection where applicable, and route borderline units to checkweighing and quality inspection before release.
Practical guidance written from engineering knowledge; it is not a statistical estimate.
1Probability and evidence
- Probability of presence
- 0.7% [0.2–2.0%]
- Expected share of lost time
- 0.4% [0.1–1.0%]
- Share of lost time when present
- 48% [37–60%]
- Studies / units
- 120 / 162
- Evidence grade
- C
Grade C: 2 to 4 studies, or an interval wider than 0.35.
2Probability by segment
- Dairy products0.8% [0.1–2.8%]18 studies
- Soft drinks, bottled water and juices0.9% [0.1–2.5%]44 studies
- Brewing, wine and spirits0.8% [0.1–2.7%]16 studies
- Bakery and pasta0.9% [0.1–3.5%]0 studies
- Meat, poultry and seafood0.8% [0.1–2.9%]6 studies
- Fruit and vegetable processing0.9% [0.1–3.2%]4 studies
- Grain and oilseed milling1.3% [0.2–4.6%]6 studies
- Sugar and confectionery0.9% [0.1–3.2%]3 studies
- Snacks, coffee, tea and other foods0.9% [0.1–3.1%]6 studies
- Animal feed and pet food0.9% [0.1–3.2%]4 studies
- Food manufacturing (unspecified or mixed)0.8% [0.1–2.8%]13 studies
3Mechanism, SCADA signature and countermeasure
Mechanism
Engineering guidanceVariability in the dosing or filling valve, flow meter drift, or changes in product viscosity and temperature cause the delivered volume or weight of product (for example oil content) to fall below specification. Separately, ingress of foreign matter, residual cleaning or sanitising agents, or microbial contamination during the filling step renders units unfit for use even when the fill level itself is correct.
How it looks in SCADA data
Engineering guidanceIn-line checkweigher or flow totaliser readings trend below the target setpoint with increasing reject counts at the filling station; dosing valve or pump actuator signals show drift or erratic cycles. Contamination events are less directly visible in SCADA but may correlate with CIP cycle timing, missed sanitation confirmations, or downstream quality-inspection reject spikes without any corresponding deviation in fill-level signals.
Countermeasure
Engineering guidanceCalibrate and periodically verify dosing valves, pumps and flow meters against reference standards, and compensate for product viscosity and temperature in the filling control logic. Reinforce cleaning and sanitation validation, use foreign-particle or seal-integrity detection where applicable, and route borderline units to checkweighing and quality inspection before release.
4Sources
- Integration of Overall Equipment Effectiveness and Six Sigma Approach to Minimize Product Defect and Machine Downtime (2023)Open sourceShare of loss events: 15.0 % · as reported: “Less Content Oil”
Show verbatim quote
Less Content Oil 676 15
- Integration of Overall Equipment Effectiveness and Six Sigma Approach to Minimize Product Defect and Machine Downtime (2023)Open sourceNumber of events: 676 units · as reported: “Less Content Oil”
Show verbatim quote
Less Content Oil 676 15
- Technical Analysis and Solutions to Reduce Scrap Rate In Liquid Filler Machine: Case Study: In Moha Soft Drink Production Line (2025)Open sourceNumber of events: 8,124 cases · as reported: “Contaminated”
Show verbatim quote
Among these, underfill defects were the most frequent, with a total of 20,598 cases, followed by uncrowned bottles with 14,508 cases, and contamination with 8,124 cases.