Operator procedural error during operations
In short
It appears in about 1 of every 100 lines studied.
When it appears, it takes on average about 56 % of the line's lost time. Reported by 1 of the 127 studies that could observe it (sparse evidence).
What happens
Production is interrupted or degraded because an operator deviates from the standard operating procedure, misjudges a manual action, or mishandles a control or setting while conducting the process. The error is human-originated rather than a mechanical or control-system fault, and its effect ripples through whichever equipment or step was being operated at the time.
What is done about it
Reinforce standard operating procedures through refresher training, visual work instructions and poka-yoke interlocks that prevent out-of-sequence actions, and review near-miss or deviation events with operators to close recurring gaps in practice.
Practical guidance written from engineering knowledge; it is not a statistical estimate.
1Probability and evidence
- Probability of presence
- 0.6% [0.1–1.5%]
- Expected share of lost time
- 0.3% [0.1–0.8%]
- Share of lost time when present
- 56% [45–66%]
- Studies / units
- 127 / 161
- Evidence grade
- D
Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.
2Probability by segment
- Dairy products0.6% [0.1–2.2%]13 studies
- Soft drinks, bottled water and juices0.6% [0.1–2.0%]26 studies
- Brewing, wine and spirits0.9% [0.1–3.3%]11 studies
- Bakery and pasta0.6% [0.1–2.0%]24 studies
- Meat, poultry and seafood0.6% [0.1–2.4%]9 studies
- Fruit and vegetable processing0.7% [0.1–2.6%]7 studies
- Grain and oilseed milling0.6% [0.1–2.3%]6 studies
- Sugar and confectionery0.6% [0.1–2.4%]9 studies
- Snacks, coffee, tea and other foods0.6% [0.1–2.5%]5 studies
- Animal feed and pet food0.6% [0.1–2.3%]7 studies
- Food manufacturing (unspecified or mixed)0.6% [0.1–2.3%]10 studies
3Mechanism, SCADA signature and countermeasure
Mechanism
Engineering guidanceProduction is interrupted or degraded because an operator deviates from the standard operating procedure, misjudges a manual action, or mishandles a control or setting while conducting the process. The error is human-originated rather than a mechanical or control-system fault, and its effect ripples through whichever equipment or step was being operated at the time.
How it looks in SCADA data
Engineering guidanceSCADA/MES logs typically show a manual mode intervention, an out-of-sequence operator action, or a parameter change entered from the HMI immediately before the stop or deviation, without any preceding equipment fault alarm. The event is often recorded under a generic or operator-attributed downtime reason code rather than a specific fault code.
Countermeasure
Engineering guidanceReinforce standard operating procedures through refresher training, visual work instructions and poka-yoke interlocks that prevent out-of-sequence actions, and review near-miss or deviation events with operators to close recurring gaps in practice.
4Sources
- Enhancing operational efficiency in craft beer production: implementation of lean manufacturing and TPM methodologies in SMES (2025)Open sourceShare of lost time: 39.2 % · as reported: “errors in the conduct of operations”
Show verbatim quote
Among the main causes identified, errors in the conduct of operations accounted for 39.20%, reprocessing constituted 13.95%, and process shutdowns due to machine failures covered 46.85%.
- Enhancing Operational Efficiency in Craft Beer Production: Implementation of Lean Manufacturing and TPM Methodologies in SMEs (2024)Open sourceShare of lost time: 39.2 % · as reported: “errors in the conduct of operations”
Show verbatim quote
errors in the conduct of operations accounted for 39.20%, reprocessing constituted 13.95%, and process shutdowns due to machine failures covered 46.85%.