Power supply disruption

In short

It appears in about 1 of every 100 lines studied.

When it appears, it takes on average about 57 % of the line's lost time. Reported by 2 of the 127 studies that could observe it (limited evidence).

What happens

An external voltage sag, outage or unstable grid supply interrupts electrical power to the line, causing drives, controllers and auxiliary equipment to lose function until power is restored. The stop originates outside the process itself, in the facility or utility electrical network rather than in a mechanical or process failure.

What is done about it

Install backup power sources such as UPS or standby generators for critical control and process equipment, and work with the utility or facility electrical team to monitor and improve supply quality. Implement surge protection, automatic transfer switches and a documented restart procedure to minimise downtime after power events.

Practical guidance written from engineering knowledge; it is not a statistical estimate.

1Probability and evidence

Pooled over all segments. A wide interval is a result: it states how much the evidence allows us to know.
Probability of presence
0.7% [0.2–1.9%]
Expected share of lost time
0.4% [0.1–1.1%]
Share of lost time when present
57% [46–68%]
Studies / units
127 / 161
Evidence grade
C

Grade C: 2 to 4 studies, or an interval wider than 0.35.

2Probability by segment

Partially pooled estimates for each industry segment.
  • Dairy products
    0.8% [0.1–2.8%]13 studies
  • Soft drinks, bottled water and juices
    1.0% [0.2–3.1%]26 studies
  • Brewing, wine and spirits
    0.8% [0.1–2.8%]11 studies
  • Bakery and pasta
    1.0% [0.2–3.4%]24 studies
  • Meat, poultry and seafood
    0.8% [0.1–2.9%]9 studies
  • Fruit and vegetable processing
    0.8% [0.1–3.0%]7 studies
  • Grain and oilseed milling
    0.8% [0.1–2.8%]6 studies
  • Sugar and confectionery
    0.8% [0.1–3.0%]9 studies
  • Snacks, coffee, tea and other foods
    0.8% [0.1–2.7%]5 studies
  • Animal feed and pet food
    0.8% [0.1–2.9%]7 studies
  • Food manufacturing (unspecified or mixed)
    0.8% [0.1–2.9%]10 studies

3Mechanism, SCADA signature and countermeasure

Engineering guidance that helps recognise and address the cause; it is not part of the statistical estimate.

Mechanism

Engineering guidance

An external voltage sag, outage or unstable grid supply interrupts electrical power to the line, causing drives, controllers and auxiliary equipment to lose function until power is restored. The stop originates outside the process itself, in the facility or utility electrical network rather than in a mechanical or process failure.

How it looks in SCADA data

Engineering guidance

SCADA shows a simultaneous loss-of-communication or fault state across multiple independent machines on the same electrical feed, often with power-quality alarms, UPS switchover events or voltage/frequency deviation logs preceding the stoppage. All line equipment transitions to a stopped or fault state at the same timestamp rather than a single machine failing first.

Countermeasure

Engineering guidance

Install backup power sources such as UPS or standby generators for critical control and process equipment, and work with the utility or facility electrical team to monitor and improve supply quality. Implement surge protection, automatic transfer switches and a documented restart procedure to minimise downtime after power events.

4Sources

Every extracted datum with its study, value and verbatim quote.
  1. Share of loss events: 16.0 % · as reported: “Power supply problems”
    Show verbatim quote
    70% das paradas de linha estavam relacionadas a problemas no equipamento da Klockner, 16% por problemas de fornecimento de energia e 9% por problemas na máquina de injetora de tinta
  2. Lost time: 419 h · as reported: “disruptions in external power supply or failures in specific equipment units”
    Show verbatim quote
    At the same time, an additional 419 hours of unplanned downtime were recorded due to disruptions in external power supply or failures in specific equipment units
  3. Mean event duration: 914 min · as reported: “Power Interruption”
    Show verbatim quote
    The Power Interruption category only happened twice; it had a high MTTR of 913.5 minutes, which brought the reliability down to 79.22%.