Pump failure
In short
It appears in about 1 of every 100 lines studied.
When it appears, it takes on average about 57 % of the line's lost time. Reported by 2 of the 127 studies that could observe it (limited evidence).
What happens
A pump (including oil/lubrication pumps supporting other equipment) loses its ability to deliver flow or pressure due to mechanical wear, seal or bearing damage, impeller blockage, loss of prime, motor or coupling failure, or electrical faults. This interrupts the fluid transfer, lubrication or hydraulic function the pump provides, stopping the dependent process or machine until repaired.
What is done about it
Apply condition-based maintenance on pumps and their lubrication circuits, including vibration monitoring, seal and bearing inspection, and scheduled oil analysis or replacement for oil pumps. Install redundant or standby pumps for critical services and configure alarms on pressure, flow and oil level to trigger early intervention before a full stop occurs.
Practical guidance written from engineering knowledge; it is not a statistical estimate.
1Probability and evidence
- Probability of presence
- 0.8% [0.2–2.0%]
- Expected share of lost time
- 0.5% [0.1–1.2%]
- Share of lost time when present
- 57% [46–67%]
- Studies / units
- 127 / 161
- Evidence grade
- C
Grade C: 2 to 4 studies, or an interval wider than 0.35.
2Probability by segment
- Dairy products1.3% [0.2–4.1%]13 studies
- Soft drinks, bottled water and juices0.8% [0.1–2.4%]26 studies
- Brewing, wine and spirits0.9% [0.1–3.2%]11 studies
- Bakery and pasta0.8% [0.1–2.5%]24 studies
- Meat, poultry and seafood0.9% [0.1–3.0%]9 studies
- Fruit and vegetable processing0.9% [0.1–3.5%]7 studies
- Grain and oilseed milling0.9% [0.1–3.2%]6 studies
- Sugar and confectionery0.9% [0.1–3.2%]9 studies
- Snacks, coffee, tea and other foods0.9% [0.1–3.0%]5 studies
- Animal feed and pet food0.9% [0.1–3.1%]7 studies
- Food manufacturing (unspecified or mixed)1.3% [0.2–4.7%]10 studies
3Mechanism, SCADA signature and countermeasure
Mechanism
Engineering guidanceA pump (including oil/lubrication pumps supporting other equipment) loses its ability to deliver flow or pressure due to mechanical wear, seal or bearing damage, impeller blockage, loss of prime, motor or coupling failure, or electrical faults. This interrupts the fluid transfer, lubrication or hydraulic function the pump provides, stopping the dependent process or machine until repaired.
How it looks in SCADA data
Engineering guidanceSCADA/MES shows the pump motor state dropping to off or fault while a running command is still active, with loss of discharge pressure or flow signal and possible low-level or low-pressure alarms upstream or downstream. The equipment fault log registers a pump fault code, and dependent machines show starvation or blocking states correlated in time with the pump stop.
Countermeasure
Engineering guidanceApply condition-based maintenance on pumps and their lubrication circuits, including vibration monitoring, seal and bearing inspection, and scheduled oil analysis or replacement for oil pumps. Install redundant or standby pumps for critical services and configure alarms on pressure, flow and oil level to trigger early intervention before a full stop occurs.
4Sources
- Number of events: 15.0 events · as reported: “Pompanın çalışmaması”
Show verbatim quote
Arıza Sayısına Göre Pareto Diyagramı 105 44 37 25 23 17 15 161 0 50 100 150 200 3 6 5 1 2 4 7 8
- Lost time: 943 min · as reported: “Pompanın çalışmaması”
Show verbatim quote
Arıza Süresine Göre Pareto Diyagramı 4727 2495 2249 2246 1408 943 638 10768 0 2000 4000 6000 8000 10000 12000 3 5 1 6 2 7 4 8
- Lost time: 411 min · as reported: “Pump Replacements”
Show verbatim quote
411 Pump Replacements
- Impact evaluation of operator training on the understanding of performance indicators (2025)Open sourceNumber of events: 12.0 occurrences · as reported: “electric pump downtime”
Show verbatim quote
a 40% decrease in electric pump downtime (from 20 to 12 occurrences)
- Impact evaluation of operator training on the understanding of performance indicators (2025)Open sourceNumber of events: 20.0 occurrences · as reported: “electric pump downtime”
Show verbatim quote
a 40% decrease in electric pump downtime (from 20 to 12 occurrences)
- Optimalisasi Perawatan Mesin untuk Meningkatkan Efisiensi Biaya dan Waktu Operasional pada Usaha Penggilingan Padi Sabar Sakdremo (2026)Open sourceLost time: 1.00 h · as reported: “Pompa oli”
Show verbatim quote
Pompa oli | Rp520.000 | Rp350.000 | 3 Jam 30 Menit | 1 Jam 0 Menit