foratvise
Get Started
Equipment failure (breakdowns)

Steam/Power Generation Utility Failure

Equipment failure (breakdowns)AvailabilityUtilities (steam, compressed air, chilled water, power)

In short

It appears in about 1 of every 100 lines studied.

When it appears, it takes on average about 58 % of the line's lost time. Reported by 1 of the 131 studies that could observe it (sparse evidence).

What happens

The boiler, turbine or generator set that supplies steam or electrical power to the plant loses function or trips, cutting off motive power, process heat or electricity to downstream equipment such as the mill. Because milling and other process steps depend entirely on this shared utility, any malfunction in combustion, feedwater, turbine or alternator subsystems propagates as a stoppage across the dependent operations.

What is done about it

Apply condition-based and preventive maintenance to boilers, turbines, generators and their auxiliaries (feedwater, combustion, lubrication, electrical protection), and provide redundancy such as a standby boiler, backup generator or alternative grid feed so that a single generation fault does not stop the dependent process lines. Monitor key utility parameters continuously to detect degradation before it causes a trip.

Practical guidance written from engineering knowledge; it is not a statistical estimate.

1Probability and evidence

Pooled over all segments. A wide interval is a result: it states how much the evidence allows us to know.
Probability of presence
0.6% [0.1–1.5%]
Expected share of lost time
0.3% [0.1–0.9%]
Share of lost time when present
58% [47–68%]
Studies / units
131 / 165
Evidence grade
D

Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.

2Probability by segment

Partially pooled estimates for each industry segment.
  • Dairy products
    0.6% [0.1–2.4%]13 studies
  • Soft drinks, bottled water and juices
    0.6% [0.1–2.0%]26 studies
  • Brewing, wine and spirits
    0.6% [0.1–2.4%]12 studies
  • Bakery and pasta
    0.6% [0.1–2.1%]25 studies
  • Meat, poultry and seafood
    0.6% [0.1–2.3%]9 studies
  • Fruit and vegetable processing
    0.7% [0.1–2.4%]7 studies
  • Grain and oilseed milling
    0.7% [0.1–2.4%]7 studies
  • Sugar and confectionery
    0.9% [0.1–3.3%]9 studies
  • Snacks, coffee, tea and other foods
    0.7% [0.1–2.4%]5 studies
  • Animal feed and pet food
    0.6% [0.1–2.3%]7 studies
  • Food manufacturing (unspecified or mixed)
    0.7% [0.1–2.5%]11 studies

3Mechanism, SCADA signature and countermeasure

Engineering guidance that helps recognise and address the cause; it is not part of the statistical estimate.

Mechanism

Engineering guidance

The boiler, turbine or generator set that supplies steam or electrical power to the plant loses function or trips, cutting off motive power, process heat or electricity to downstream equipment such as the mill. Because milling and other process steps depend entirely on this shared utility, any malfunction in combustion, feedwater, turbine or alternator subsystems propagates as a stoppage across the dependent operations.

How it looks in SCADA data

Engineering guidance

Utility SCADA/MES shows boiler or turbine trip alarms, loss of steam header pressure or electrical bus voltage, generator fault codes, and simultaneous transition of downstream equipment (e.g., mill drives) to idle or stopped state correlated with the utility alarm timestamp. Event logs typically pair a single generation-side fault with multiple dependent-area downtime records of similar duration.

Countermeasure

Engineering guidance

Apply condition-based and preventive maintenance to boilers, turbines, generators and their auxiliaries (feedwater, combustion, lubrication, electrical protection), and provide redundancy such as a standby boiler, backup generator or alternative grid feed so that a single generation fault does not stop the dependent process lines. Monitor key utility parameters continuously to detect degradation before it causes a trip.

4Sources

Every extracted datum with its study, value and verbatim quote.
  1. Time between events: 4.92 log(min) · as reported: “Operating - Steam Generation”
    Show verbatim quote
    Operating - Steam Generation 135 4.924 (4.628; 5.220)
  2. Time between events: 6.43 log(min) · as reported: “Operating - Power Generation”
    Show verbatim quote
    Operating - Power Generation 5 6.429 (4.890; 7.969)
  3. Number of events: 5.00 events · as reported: “Operating - Power Generation”
    Show verbatim quote
    Operating - Power Generation 5 6.429 (4.890; 7.969)
  4. Number of events: 135 events · as reported: “Operating - Steam Generation”
    Show verbatim quote
    Operating - Steam Generation 135 4.924 (4.628; 5.220)
  5. Number of events: 53.0 events · as reported: “Steam generation (GVAP)”
    Show verbatim quote
    GVAP 53 119,1 150,3 22580,0 52,2
  6. Mean event duration: 119 min · as reported: “Steam generation (GVAP)”
    Show verbatim quote
    GVAP 53 119,1 150,3 22580,0 52,2
  7. Number of events: 20.0 events · as reported: “Energy generation”
    Show verbatim quote
    Geração de energia 20 108,8 111,9 12519,0 64,8
  8. Mean event duration: 109 min · as reported: “Energy generation”
    Show verbatim quote
    Geração de energia 20 108,8 111,9 12519,0 64,8
  9. Number of events: 41.0 events · as reported: “Steam generation”
    Show verbatim quote
    Geraçao de vapor 41 93,1 116,1 13480,3 45,0
  10. Mean event duration: 93.1 min · as reported: “Steam generation”
    Show verbatim quote
    Geraçao de vapor 41 93,1 116,1 13480,3 45,0