V-belt breakage or slippage
In short
It appears in fewer than 1 of every 100 lines studied.
When it appears, it takes on average about 58 % of the line's lost time. Reported by 0 of the 127 studies that could observe it (sparse evidence).
What happens
The V-belt that transmits motion between motor and driven shaft wears, loses tension, becomes misaligned or ages until it cracks, stretches excessively or snaps, so the mechanical power transmission to the driven component (mill rotor, separator drive, etc.) is interrupted or degraded.
What is done about it
Implement periodic inspection and replacement of belts based on wear and tension condition, ensure correct pulley alignment and tensioning during installation, and consider belt tension or vibration monitoring to anticipate failure before it causes an unplanned stop.
Practical guidance written from engineering knowledge; it is not a statistical estimate.
1Probability and evidence
- Probability of presence
- 0.4% [0.1–1.1%]
- Expected share of lost time
- 0.2% [0.0–0.6%]
- Share of lost time when present
- 58% [47–68%]
- Studies / units
- 127 / 161
- Evidence grade
- D
Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.
2Probability by segment
- Dairy products0.4% [0.0–1.7%]13 studies
- Soft drinks, bottled water and juices0.4% [0.0–1.5%]26 studies
- Brewing, wine and spirits0.4% [0.0–1.6%]11 studies
- Bakery and pasta0.4% [0.0–1.5%]24 studies
- Meat, poultry and seafood0.4% [0.0–1.6%]9 studies
- Fruit and vegetable processing0.4% [0.0–1.7%]7 studies
- Grain and oilseed milling0.4% [0.0–1.7%]6 studies
- Sugar and confectionery0.4% [0.0–1.7%]9 studies
- Snacks, coffee, tea and other foods0.4% [0.0–1.7%]5 studies
- Animal feed and pet food0.4% [0.0–1.7%]7 studies
- Food manufacturing (unspecified or mixed)0.4% [0.0–1.7%]10 studies
3Mechanism, SCADA signature and countermeasure
Mechanism
Engineering guidanceThe V-belt that transmits motion between motor and driven shaft wears, loses tension, becomes misaligned or ages until it cracks, stretches excessively or snaps, so the mechanical power transmission to the driven component (mill rotor, separator drive, etc.) is interrupted or degraded.
How it looks in SCADA data
Engineering guidanceMotor keeps running at normal or reduced current while driven shaft speed, torque or output flow drops toward zero; drive fault or underload alarm appears, and the machine state log shows an unplanned stop with downstream starvation on the affected unit.
Countermeasure
Engineering guidanceImplement periodic inspection and replacement of belts based on wear and tension condition, ensure correct pulley alignment and tensioning during installation, and consider belt tension or vibration monitoring to anticipate failure before it causes an unplanned stop.
4Sources
- Riplle Mill Machine Failure Analysis Using the Failure Mode and Effect Analysis (FMEA) Method at PT. Ujong Neubok In (2023)Open sourceTime between events: 6.00 Months · as reported: “V-Belt”
Show verbatim quote
V-Belt Break 6 Months
- Analysis Of Overall Equipment Effectiveness (OEE) Rice Milling Unit Machines to At CV Fajar Samudra (2025)Open sourceMean event duration: 4.00 jam · as reported: “v-belt mesin putus/kendor”
Show verbatim quote
Berdasarkan informasi dari pemilik perusahaan permasalahan yang terjadi pada mesin pengiling beras (Rice Milling Unit) yakni v-belt putus atau kendor sehingga mengakibatkan mesin berhenti dan tidak beroperasi + selama 4 jam.