In short
It appears in about 1 of every 100 lines studied.
When it appears, it takes on average about 56 % of the line's lost time. Reported by 3 of the 120 studies that could observe it (limited evidence).
What happens
The filler and its product-contact piping are taken offline so that an automated Clean-in-Place sequence can circulate rinse, caustic/acid and sanitizing solutions through the system, interrupting production while the cycle runs. This cleaning is normally required between product changes or at scheduled hygiene intervals to meet food-safety standards before the next run can start.
What is done about it
Standardize and automate the CIP recipe with sensor-based endpoint detection (conductivity, turbidity) to avoid over-cleaning, schedule CIP within planned changeover or shift-break windows, and use a dedicated CIP supply skid or parallel circuits so the filler can be returned to production as soon as the sanitary verification is complete.
Practical guidance written from engineering knowledge; it is not a statistical estimate.
1Probability and evidence
- Probability of presence
- 0.9% [0.2–2.2%]
- Expected share of lost time
- 0.5% [0.1–1.2%]
- Share of lost time when present
- 56% [44–67%]
- Studies / units
- 120 / 162
- Evidence grade
- C
Grade C: 2 to 4 studies, or an interval wider than 0.35.
2Probability by segment
- Dairy products1.3% [0.2–4.1%]18 studies
- Soft drinks, bottled water and juices1.3% [0.3–3.4%]44 studies
- Brewing, wine and spirits0.9% [0.1–3.0%]16 studies
- Bakery and pasta1.0% [0.1–3.5%]0 studies
- Meat, poultry and seafood1.0% [0.1–3.5%]6 studies
- Fruit and vegetable processing1.0% [0.1–3.6%]4 studies
- Grain and oilseed milling1.0% [0.1–3.6%]6 studies
- Sugar and confectionery1.0% [0.1–3.5%]3 studies
- Snacks, coffee, tea and other foods1.0% [0.1–3.3%]6 studies
- Animal feed and pet food1.0% [0.1–3.7%]4 studies
- Food manufacturing (unspecified or mixed)1.0% [0.1–3.4%]13 studies
3Mechanism, SCADA signature and countermeasure
Mechanism
Engineering guidanceThe filler and its product-contact piping are taken offline so that an automated Clean-in-Place sequence can circulate rinse, caustic/acid and sanitizing solutions through the system, interrupting production while the cycle runs. This cleaning is normally required between product changes or at scheduled hygiene intervals to meet food-safety standards before the next run can start.
How it looks in SCADA data
Engineering guidanceSCADA/MES logs show the filler and CIP skid transitioning into a dedicated CIP or cleaning machine state, with valve sequencing, flow, temperature and conductivity trends confirming each rinse/wash/sanitize step; the filler state duration accumulates as changeover or non-production time and downstream stations show starvation while the cycle completes.
Countermeasure
Engineering guidanceStandardize and automate the CIP recipe with sensor-based endpoint detection (conductivity, turbidity) to avoid over-cleaning, schedule CIP within planned changeover or shift-break windows, and use a dedicated CIP supply skid or parallel circuits so the filler can be returned to production as soon as the sanitary verification is complete.
4Sources
- ANALISIS PERHITUNGAN EFEKTIFITAS MESIN FILLER LINE LAB MENGGUNAKAN METODE OVERALL EQUIPMENT EFFECTIVENESS (OEE) (Studi Kasus di PT. X) (2016)Open sourceLost time: 49.7 jam · as reported: “CIP (clean in proses)”
Show verbatim quote
Total 107.61 6.469 638.570 49.660
- Share of lost time: 15.0 % · as reported: “CIP processes”
Show verbatim quote
Specifically,label changeovers account for a 16% loss,followed closely by CIP processes at 15% and size changeovers at 8.9%.
- IMPLEMENTATION OF TPM ( TOTAL PRODUCTIVE MAINTENANCE) METHOD ON FILLING LINE 4 MACHINE TO REDUCE REJECTS AND DOWNTIME AT PT.XYZ (2025)Open sourceLost time: 2,509 min · as reported: “CIP (Cleaning In Place)”
Show verbatim quote
In the month February – May 2019 recorded existence minor idling downtime stop at line 4 , namely , CIP ( Cleaning In Place ) 2,509 minutes , SIP ( Sanitation In Place ) 1,943 minutes , stuck stamp on track 484 minutes , bottle stuck in the SIPA 322 divider , tilting was stuck for 277 minutes and the pallet ran out for 93 minutes .