Pasteurization
Continuous (HTST) pasteurization with regenerative heat exchange
In short
Pasteurization can use at most 98 of every 100 planned hours. The rest goes to limits no plant can avoid.
- 98usable at most
- 2are a physical limit
The three limits that set it
Running time: up to 98 %
The rest are stops imposed by physics or by regulation: cleaning, changeovers, defrosting.
Speed: up to 100 %
How close to its maximum speed it can run without damaging the product or the equipment.
Good product: up to 100 %
Some product falls outside specification even with the process well under control.
Technical detail
Uncertainty intervals, physical models per station and sources, for anyone who wants to check each figure.
1Scenario
Whole milk enters a plate heat exchanger at storage temperature, is heated to the legal pasteurization temperature, held for the legal holding time in a holding tube and cooled back to storage temperature. Heating and cooling are partly provided by regeneration (hot pasteurized milk preheats cold raw milk).
2Results
- TheoreticalThermodynamic minimum external thermal duty0 kJ/kg
- Best available techniqueExternal thermal duty (heating + cooling) with best available regeneration26.8 [25.8–27.9] kJ/kg
- TypicalExternal thermal duty (heating + cooling) with regeneration in operation80.4 [48.9–80.4] kJ/kg
- Thermal duty (heating + cooling) without regeneration536 [517–558] kJ/kg
- Ideal (Carnot) refrigeration work for the residual cooling duty at best available regeneration1.02 [0.52–1.53] kJ/kg
- Number of transfer units required by the best available regeneration19.0
- TheoreticalMinimum holding time of the fastest particle15.0 s
- Minimum mean residence time in the holding tube, turbulent flow18.4 s
- Holding-tube utilisation relative to ideal plug flow (turbulent)0.817
- TheoreticalMaximum throughput per unit of holding-tube volume (turbulent)196 1/h
- Reynolds number in the product line70,944 [34,599–122,524]
- TheoreticalMaximum availability (daily cleaning as the only stop)0.9844 [0.9791–0.9886]
- Best documentedAvailability with the documented fouling-limited run and the minimum cleaning time0.958 [0.944–0.969]
- TypicalAvailability with the fouling-limited run and a typical cleaning programme0.850 [0.809–0.893]
- Share of product diverted for low temperature0.00135 [0.00026–0.00579]
- Share of product lost in the start-up and shut-down mixing zones7.84 × 10⁻⁵ [4.51 × 10⁻⁵–1.73 × 10⁻⁴]
- TheoreticalMaximum yield0.99992 [0.99983–0.99995]
- TheoreticalMaximum OEE quality factor (diverts and start-up losses)0.9986 [0.9941–0.9997]
- TheoreticalMaximum performance factor (reference: legal-maximum rate of the holding tube)1.00
- TheoreticalPhysics-bounded OEE0.983 [0.976–0.987]
3Ceilings per dimension
- Theoretical
- Best available technique
- Best documented
- Typical
- TheoreticalThermodynamic minimum external thermal duty0 kJ/kg
- TheoreticalDOE bandwidth study, thermodynamic minimum energy intensity for fluid milk · Benchmark0 kJ/kg
- Best available techniqueExternal thermal duty (heating + cooling) with best available regeneration26.8 [25.8–27.9] kJ/kg
- Best available techniqueDOE bandwidth study, fluid milk pasteurization step, state-of-the-art on-site energy intensity (same boundary as the current typical value) · Benchmark90.7 kJ/kg
- TypicalExternal thermal duty (heating + cooling) with regeneration in operation80.4 [48.9–80.4] kJ/kg
- TypicalReported specific energy with regeneration in an example dairy (heating plus cooling, 4 to 78 °C; regeneration to 65 °C, i.e. an effectiveness of about 82 %, below the 85 % lower bound of the typical range, hence classed as typical, not as best documented) · Benchmark121 kJ/kg
- TypicalDOE bandwidth study, fluid milk pasteurization step, current typical on-site energy intensity (heating step only, fuel and electricity at the plant including boiler and distribution losses; a wider boundary than the product-side thermal duty of this model, and cooling is a separate DOE step) · Benchmark214 kJ/kg
- TypicalReported specific energy without regeneration (heating plus cooling, 4 to 78 °C) · Benchmark619 kJ/kg
- TheoreticalMinimum holding time of the fastest particle15.0 s
- TheoreticalMaximum throughput per unit of holding-tube volume (turbulent)196 1/h
- TheoreticalMaximum availability (daily cleaning as the only stop)0.9844 [0.9791–0.9886]
- Best documentedAvailability with the documented fouling-limited run and the minimum cleaning time0.958 [0.944–0.969]
- TypicalAvailability with the fouling-limited run and a typical cleaning programme0.850 [0.809–0.893]
- TheoreticalMaximum yield0.99992 [0.99983–0.99995]
- TheoreticalMaximum OEE quality factor (diverts and start-up losses)0.9986 [0.9941–0.9997]
- TheoreticalMaximum performance factor (reference: legal-maximum rate of the holding tube)1.00
- TheoreticalPhysics-bounded OEE0.983 [0.976–0.987]
4Loss cascade
- TypicalBest available techniqueEnergy per unit of product80.4 [48.9–80.4] kJ/kg → 26.8 [25.8–27.9] kJ/kg (gap 53.6 kJ/kg)
Regeneration effectiveness in operation (85–91 %) against the best available plate exchangers (95 %): every point of effectiveness removes 1 % of the no-regeneration duty. The gap is exchange area and plate condition (fouling lowers the overall heat-transfer coefficient during the run).
- Best available techniqueTheoreticalEnergy per unit of product26.8 [25.8–27.9] kJ/kg → 0 kJ/kg (gap 26.8 kJ/kg)
The remaining 5 % is the irreversibility of heat transfer across a finite temperature difference: closing it needs the number of transfer units to grow without bound (NTU = 19 at 95 %, 99 at 99 %), i.e. unbounded exchange area and pressure drop. The thermodynamic minimum of zero is an asymptote, not a design point.
- TypicalBest documentedAvailability0.850 [0.809–0.893] → 0.958 [0.944–0.969] (gap 0.108)
A typical cleaning programme lasts longer than the physical minimum of its phases (operating margins, heating and draining times, manual steps). With a fouling-limited run of 8–9 h, each extra half hour of cleaning costs about five points of availability.
- Best documentedTheoreticalAvailability0.958 [0.944–0.969] → 0.9844 [0.9791–0.9886] (gap 0.0266)
Fouling of the heating surfaces by denatured whey protein and calcium phosphate forces cleaning after 8–9 h; the regulation only demands one cleaning per day of use. The gap is the fouling rate, which depends on surface temperature, shear and milk quality: it is physical in origin but not a fixed limit.
5Physics-bounded OEE
- Loading time (ideal)1.000
- Availabilityfactor 0.9844 [0.9791–0.9886]0.984 (−0.016)
- Performancefactor 1.000.984 (−0.000)
- Qualityfactor 0.9986 [0.9941–0.9997]0.983 (−0.001)
- Physics-bounded OEE0.983 [0.976–0.987]
6Full derivation
Scope. Whole milk in continuous flow through a plate heat exchanger with a regeneration section, a final heater, a holding tube and a cooler. Symbols and their values, units, uncertainty distributions and sources are listed in the parameter table generated from config/physics/pasteurization.yaml.
1. Mass balance — maximum yield
There is no phase change, no reaction that consumes product and no stream split, so the steady-state mass balance is and the steady-state yield is exactly 1. Product can only be lost in transients: at start-up the line is full of water that the product displaces, and at shut-down water displaces the product. Each displacement creates a mixing zone that cannot be sold as product.
The physical lower bound of that zone is set by axial dispersion in turbulent pipe flow. Taylor's result for the axial dispersion coefficient in a pipe of radius is
where is the friction velocity, the mean velocity and the Darcy friction factor (Blasius correlation for a smooth pipe, , ). After travelling a length in time , an initially sharp interface has a Gaussian concentration profile of standard deviation . Taking the zone between 1% and 99% of product concentration as lost,
With one zone at start-up and one at shut-down per production run of duration at flow rate :
Losses in tanks, valves, dead legs and filters are properties of the installed technology, not of physics, and belong to the gap between the theoretical ceiling and the best documented operation.
2. Energy balance — minimum energy per unit of product
Treat milk as an incompressible liquid with constant . The product enters at and leaves at the same storage temperature, so its net enthalpy change is
Thermodynamic minimum. A process that returns the product to its initial state requires no net energy in the reversible limit: all the heat given to the product while heating can be recovered from it while cooling. The thermodynamic minimum external duty is therefore zero. This agrees with the thermodynamic minimum of 0 Btu/lb that the US DOE bandwidth study assigns to fluid milk.
Finite exchangers. Regeneration is a balanced counter-current exchange (both streams have the same capacity rate ). Its effectiveness is
so only as the exchange area : the zero minimum is approached asymptotically, never reached. With set-point temperature (legal temperature plus the control margin), the external duties are
and the total external thermal duty reported here is . Without regeneration () it is . The residual cooling duty costs at least the Carnot work when heat is rejected at ambient temperature .
The three energy ceilings. Theoretical: 0. Best available technique: = 95% regeneration. Typical operation: regeneration effectiveness between 85% and 91%. The example dairy of the BAT reference document (regeneration to 65 °C in a 4–78 °C process, an effectiveness of about 82%) and the DOE on-site intensity of the pasteurization step of fluid milk (a wider boundary that includes boiler and distribution losses) are listed as typical benchmarks; the DOE state-of-the-art value is listed against the best available technique.
3. Rate-limiting step — minimum cycle time and maximum throughput
The rate-limiting step is not heat transfer but the kinetics of microbial inactivation. Every particle of product must spend at least the holding time at or above the pasteurization temperature; regulators fix the pair (72 °C, 15 s) and define the holding time as the flow time of the fastest particle.
In a holding tube of volume the mean residence time is , but the fastest particle travels at . Hence
- Laminar flow (Hagen–Poiseuille parabolic profile): , the value the regulation itself imposes for high-viscosity products.
- Turbulent flow (one-seventh power law , ): integrating the profile over the cross-section gives , i.e. .
The plug-flow efficiency is the share of a holding tube's volume that the legal rule lets a plant use, relative to ideal plug flow: 0.82 in turbulent flow, 0.50 in laminar flow. It sizes the holding tube; it is not the OEE performance factor, whose reference rate is the legal maximum below. The minimum mean residence time is = 18.4 s, and the maximum throughput per unit of holding volume is = 196 volumes per hour.
A plant whose nameplate rate equals this legal maximum has an OEE performance factor of 1 at that rate; running faster is not a performance gain but a legal violation.
4. Process capability — quality ceiling
The outlet temperature of the holding tube under closed-loop control is modelled as . Product below is automatically diverted and reprocessed. With the set point standard deviations above the legal temperature, the diverted share is
The margin costs energy, , which is small; the capability ceiling is therefore set by the margin the operator accepts ( gives ).
5. Unavoidable stops — maximum availability
Milk proteins and minerals foul the heating surfaces, and hygiene regulation requires that equipment be cleaned at least once each day of use. The minimum duration of the cleaning, , is taken through a parameter link from the cleaning model (output cip_time_min, with its Monte Carlo interval): the physical minimum of the kinetic and displacement phases (removal kinetics of the deposit, plug-flow displacement with axial dispersion) plus the declared acid and sanitising hold times. With a cleaning cycle = 24 h,
Two further availability levels are reported. The documented level replaces the 24 h cycle by the fouling-limited run length that the BAT reference document gives for indirect milk heat exchangers (8–9 h), keeping the minimum cleaning time: . The typical level uses the same run with a typical cleaning programme: .
6. Physics-bounded OEE
Scope of the bound. The theoretical label of means physics-bounded under the declared scenario: the ceiling follows from the physics of the operation for the declared product, equipment and schedule, and it is a bound only conditional on those declarations. It follows the common definition of all models: counts only stops required by regulation or forced by a physical mechanism, at their physical minimum duration, plus the start-up they force; is the ratio of the physics-limited ideal cycle to the cycle of the capable process; is the share of conforming units, and mass losses of conforming product are reported only as yield.
refers to the legal-maximum rate of Section 3. The result, with the Monte Carlo interval over the declared uncertainty of every input, is reported in the output table.
7. Assumptions and validity
See the assumption and validity lists generated from the configuration file. The most influential inputs (sensitivity table) are the cleaning duration and the regeneration effectiveness.
References
- U.S. Food and Drug Administration. Grade "A" Pasteurized Milk Ordinance, 2023 Revision.
- European Commission, Joint Research Centre. Best Available Techniques (BAT) Reference Document for the Food, Drink and Milk Industries, 2019.
- U.S. Department of Energy. Bandwidth Study on Energy Use and Potential Energy Savings Opportunities in U.S. Food and Beverage Manufacturing, 2017.
- Taylor, G. I. (1954). The dispersion of matter in turbulent flow through a pipe. Proceedings of the Royal Society A, 223, 446–468. doi:10.1098/rspa.1954.0130
- Bell, I. H., Wronski, J., Quoilin, S., Lemort, V. (2014). Pure and pseudo-pure fluid thermophysical property evaluation and the open-source thermophysical property library CoolProp. Industrial & Engineering Chemistry Research, 53, 2498–2508. doi:10.1021/ie4033999
7Parameters and provenance
- 4 °C
Storage temperature of the milk: inlet of the raw milk and outlet of the pasteurized milk
Scenario · Uniform 2 to 6 °C
Verified quoteShow verbatim quote
initial temperature of 4 °CBest Available Techniques (BAT) Reference Document for the Food, Drink and Milk Industries (opens in a new tab). European Commission, Joint Research Centre; Publications Office of the European Union, 2019. p. 365. EUR 29978 EN; JRC118627; doi:10.2760/243911
- 72 °C
Legal minimum pasteurization temperature (continuous flow)
Regulatory · Fixed
Verified quoteShow verbatim quote
Continuous Flow (HTST and HHST) Pasteurization Temperature Time 72°C (161°F)* 15 secondsGrade "A" Pasteurized Milk Ordinance, 2023 Revision (opens in a new tab). U.S. Department of Health and Human Services, Public Health Service, Food and Drug Administration, 2023. p. 35. PMO 2023 Revision
- 15 s
Legal minimum holding time at the pasteurization temperature
Regulatory · Fixed
Verified quoteShow verbatim quote
Continuous Flow (HTST and HHST) Pasteurization Temperature Time 72°C (161°F)* 15 secondsGrade "A" Pasteurized Milk Ordinance, 2023 Revision (opens in a new tab). U.S. Department of Health and Human Services, Public Health Service, Food and Drug Administration, 2023. p. 35. PMO 2023 Revision
- 3
Set-point margin above the legal temperature, in standard deviations of the controlled temperature
Scenario · Uniform 2.5 to 3.5
Declared assumptionOperating choice; the point value 3 is the centre of the declared range 2.5-3.5. A larger margin drives the divert rate to zero at an energy cost of (1 - eps) cp per kelvin, so the capability ceiling is set by the margin the operator accepts.
- 0.25 K
Standard deviation of the holding-tube outlet temperature under control
Scenario · Uniform 0.1 to 0.5 K
Declared assumptionProcess-capability assumption; replace with the measured value of the plant.
- 3.9 kJ/kg/K
Specific heat capacity of whole milk (composition model of Choi and Okos at the mean process temperature)
Property · Normal, sd 0.04 kJ/kg/K
Computedmeo.physics.foodprops.cp(composition=whole_milk, T=38 °C); composition and coefficients are cited in config/physics/food_properties.yaml.
- 0.85
Regeneration effectiveness of plate pasteurizers in operation (lower documented value)
Benchmark · Uniform 0.85 to 0.91
Verified quoteShow verbatim quote
Calculations were made for increasing the efficiency from 85 % to 91 % or from 91 % to 95 %.Best Available Techniques (BAT) Reference Document for the Food, Drink and Milk Industries (opens in a new tab). European Commission, Joint Research Centre; Publications Office of the European Union, 2019. p. 366. EUR 29978 EN; JRC118627; doi:10.2760/243911
- 0.95
Regeneration effectiveness of best available plate pasteurizers
Benchmark · Fixed
Verified quoteShow verbatim quote
Calculations were made for increasing the efficiency from 85 % to 91 % or from 91 % to 95 %.Best Available Techniques (BAT) Reference Document for the Food, Drink and Milk Industries (opens in a new tab). European Commission, Joint Research Centre; Publications Office of the European Union, 2019. p. 366. EUR 29978 EN; JRC118627; doi:10.2760/243911
- 25 °C
Ambient (heat-rejection) temperature for the ideal refrigeration work
Scenario · Uniform 15 to 35 °C
Declared assumption - 1.2245
Ratio of the fastest particle to the mean velocity in turbulent pipe flow (one-seventh power law)
Property · Fixed
Computed(n+1)(2n+1)/(2n^2) with n = 7; derivation in physics_docs/pasteurization.en.md, section 3.
- 2
Ratio of the fastest particle to the mean velocity in laminar pipe flow
Regulatory · Fixed
Verified quoteShow verbatim quote
laminar flow (the fastest flowing particle travels twice as fast as the average flowing particle)Grade "A" Pasteurized Milk Ordinance, 2023 Revision (opens in a new tab). U.S. Department of Health and Human Services, Public Health Service, Food and Drug Administration, 2023. p. 124. PMO 2023 Revision
- 24 h
Maximum interval between two cleanings of the equipment
Regulatory · Fixed
Verified quoteShow verbatim quote
all equipment is thoroughly cleaned at least once each day usedGrade "A" Pasteurized Milk Ordinance, 2023 Revision (opens in a new tab). U.S. Department of Health and Human Services, Public Health Service, Food and Drug Administration, 2023. p. 98. PMO 2023 Revision
- 0.374294 h
Minimum duration of a full cleaning-in-place programme: physical minimum of the kinetic and displacement phases plus declared hold times (output cip_time_min of the cleaning model, with its Monte Carlo interval)
Property · Triangular 0.242184, 0.374294, 0.536161 h
ComputedOutput `cip_time_min` of the cleaning model: 22.46 min [14.53, 32.17].
- 8.5 h
Documented run length of indirect milk heat exchangers before cleaning (fouling-limited)
Benchmark · Uniform 8 to 9 h
Verified quoteShow verbatim quote
indirect heat exchangers have to be cleaned no more than 8–9 hours after start-upBest Available Techniques (BAT) Reference Document for the Food, Drink and Milk Industries (opens in a new tab). European Commission, Joint Research Centre; Publications Office of the European Union, 2019. p. 401. EUR 29978 EN; JRC118627; doi:10.2760/243911
- 1.5 h
Duration of a typical cleaning-in-place programme in operation
Scenario · Uniform 1 to 2 h
Declared assumptionDeclared assumption for the typical programme (rinse, alkaline wash, rinse, acid wash, rinse, sanitization with operating margins). Replace with the validated programme of the plant.
- 0.051 m
Inner diameter of the product line used for the interface-mixing estimate
Scenario · Fixed
Declared assumption - 150 m
Equivalent length of product path between balance tank and filler valve
Scenario · Uniform 80 to 250 m
Declared assumption - 20 m³/h
Nominal volumetric flow rate
Scenario · Uniform 10 to 30 m³/h
Declared assumption - 1,023 kg/m³
Density of whole milk (composition model at 20 °C)
Property · Normal, sd 5 kg/m³
Computedmeo.physics.foodprops.density(composition=whole_milk, T=20 °C) = 1023 kg/m3; composition and coefficients are cited in config/physics/food_properties.yaml.
- 0.002 Pa·s
Dynamic viscosity used for the Reynolds number (water at 20 °C from IAPWS through CoolProp
Property · Uniform 0.0015 to 0.0025 Pa·s
Declared assumptionDeclared assumption: CoolProp PropsSI('V','T',293.15,'P',101325,'Water') = 1.0e-3 Pa s multiplied by a conservative factor of 2 for milk (range 1.5-2.5); the factor, not the water value, sets the parameter, so it is a scenario.
8Benchmarks
| Benchmark | Ceiling | Value | Provenance |
|---|---|---|---|
Reported specific energy without regeneration (heating plus cooling, 4 to 78 °C)Show verbatim quotethe specific energy consumption of 148 000 kcal/t (619 232 kJ/t) can be reduced by 80 %, i.e. to 29 000 kcal/t (121 336 kJ/t)Best Available Techniques (BAT) Reference Document for the Food, Drink and Milk Industries (opens in a new tab). European Commission, Joint Research Centre; Publications Office of the European Union, 2019. p. 365. EUR 29978 EN; JRC118627; doi:10.2760/243911 | Typical | 619.232 kJ/kg | Verified quote |
Reported specific energy with regeneration in an example dairy (heating plus cooling, 4 to 78 °C; regeneration to 65 °C, i.e. an effectiveness of about 82 %, below the 85 % lower bound of the typical range, hence classed as typical, not as best documented)Show verbatim quotethe specific energy consumption of 148 000 kcal/t (619 232 kJ/t) can be reduced by 80 %, i.e. to 29 000 kcal/t (121 336 kJ/t)Best Available Techniques (BAT) Reference Document for the Food, Drink and Milk Industries (opens in a new tab). European Commission, Joint Research Centre; Publications Office of the European Union, 2019. p. 365. EUR 29978 EN; JRC118627; doi:10.2760/243911 | Typical | 121.336 kJ/kg | Verified quote |
DOE bandwidth study, fluid milk pasteurization step, current typical on-site energy intensity (heating step only, fuel and electricity at the plant including boiler and distribution losses; a wider boundary than the product-side thermal duty of this model, and cooling is a separate DOE step)Show verbatim quoteFluid Milk Pasteurization 92 39 16 0Bandwidth Study on Energy Use and Potential Energy Savings Opportunities in U.S. Food and Beverage Manufacturing (opens in a new tab). U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, Advanced Manufacturing Office, 2017. p. 56. DOE/EE-1571; OSTI ID 1512366 | Typical | 92 Btu/lb | Verified quote |
DOE bandwidth study, fluid milk pasteurization step, state-of-the-art on-site energy intensity (same boundary as the current typical value)Show verbatim quoteFluid Milk Pasteurization 92 39 16 0Bandwidth Study on Energy Use and Potential Energy Savings Opportunities in U.S. Food and Beverage Manufacturing (opens in a new tab). U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, Advanced Manufacturing Office, 2017. p. 56. DOE/EE-1571; OSTI ID 1512366 | Best available technique | 39 Btu/lb | Verified quote |
DOE bandwidth study, thermodynamic minimum energy intensity for fluid milkShow verbatim quoteFluid Milk 0 192,877 0Bandwidth Study on Energy Use and Potential Energy Savings Opportunities in U.S. Food and Beverage Manufacturing (opens in a new tab). U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, Advanced Manufacturing Office, 2017. p. 26. DOE/EE-1571; OSTI ID 1512366 | Theoretical | 0 Btu/lb | Verified quote |
Lowest documented milk loss among dairy process types (share of milk processed; a loss, not a yield fraction, and from butter making and skimmed-milk transport, not market-milk pasteurization: not comparable with yield_max)Show verbatim quoteButter/transport of skimmed milk 0.17 0.14Best Available Techniques (BAT) Reference Document for the Food, Drink and Milk Industries (opens in a new tab). European Commission, Joint Research Centre; Publications Office of the European Union, 2019. p. 353. EUR 29978 EN; JRC118627; doi:10.2760/243911 | Best documented | 0.17 % | Verified quote |
9Unavoidable stops
- Cleaning at least once per day of useVerified quote
Hygiene regulation: equipment must be cleaned at least once each day used. The theoretical ceiling uses this daily cycle with the minimum duration of the cleaning programme from the cleaning model (physical minimum of the kinetic and displacement phases plus declared hold times); the documented ceiling uses the fouling-limited run length of indirect milk heat exchangers.
Show verbatim quote
all equipment is thoroughly cleaned at least once each day usedGrade "A" Pasteurized Milk Ordinance, 2023 Revision (opens in a new tab). U.S. Department of Health and Human Services, Public Health Service, Food and Drug Administration, 2023. p. 98. PMO 2023 Revision
10Assumptions
- Milk is treated as an incompressible liquid with constant specific heat over 4–72 °C; heat losses to the surroundings are neglected (they can only increase consumption).
- Regeneration is a balanced counter-current exchange (equal capacity rates), so effectiveness equals NTU/(1+NTU).
- The legal time–temperature pair is taken as a hard constraint: the physical rate limit of the operation is the microbial inactivation kinetics as codified by the regulator.
- Outlet temperature under control is normally distributed; product below the legal temperature is diverted and counted as a quality loss (it is reprocessed, not destroyed).
- Start-up and shut-down losses are bounded by the product–water mixing zone computed with Taylor's axial dispersion in turbulent pipe flow; losses in tanks, valves and dead legs are technology, not physics.
11Range of validity
- Newtonian liquid products pasteurized in continuous flow at 72 °C / 15 s (milk, and products with comparable viscosity).
- Reynolds number in the holding tube above 4 000 for the turbulent velocity ratio; below 2 100 the laminar ratio of the regulation applies.
12Sensitivity
- Maximum interval between two cleanings of the equipmentelasticity +0.016Spearman ρ —
- Minimum duration of a full cleaning-in-place programme: physical minimum of the kinetic and displacement phases plus declared hold times (output cip_time_min of the cleaning model, with its Monte Carlo interval)elasticity -0.016Spearman ρ -0.84
- Set-point margin above the legal temperature, in standard deviations of the controlled temperatureelasticity +0.014Spearman ρ +0.50
- Inner diameter of the product line used for the interface-mixing estimateelasticity 0.000Spearman ρ —
- Nominal volumetric flow rateelasticity 0.000Spearman ρ +0.01
- Equivalent length of product path between balance tank and filler valveelasticity 0.000Spearman ρ 0.00
- Density of whole milk (composition model at 20 °C)elasticity 0.000Spearman ρ 0.00
- Dynamic viscosity used for the Reynolds number (water at 20 °C from IAPWS through CoolPropelasticity 0.000Spearman ρ -0.01
- Output rises with the parameter
- Output falls with the parameter
13Validation checks
- Dimensional analysis20 outputs converted to their declared unitsPassed
- Every cited value verified against its source15 verified, 0 failedPassed
- No documented value beats the theoretical limitPassed
- Ceilings in physical orderPassed
- Fractions within 0 and 1Passed
14Causes of loss in this operation
- Off-spec liquid product from pasteurized base tankProcess defects (scrap and rework)1.0% [0.2–3.4%]D26 studies
- Manual bottle pushing in pasteurizerSetup and adjustments0.5% [0.1–1.9%]D26 studies
15References
- Grade "A" Pasteurized Milk Ordinance, 2023 Revision (opens in a new tab). U.S. Department of Health and Human Services, Public Health Service, Food and Drug Administration, 2023. p. 35. PMO 2023 Revision
- Best Available Techniques (BAT) Reference Document for the Food, Drink and Milk Industries (opens in a new tab). European Commission, Joint Research Centre; Publications Office of the European Union, 2019. p. 365. EUR 29978 EN; JRC118627; doi:10.2760/243911
- Bandwidth Study on Energy Use and Potential Energy Savings Opportunities in U.S. Food and Beverage Manufacturing (opens in a new tab). U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, Advanced Manufacturing Office, 2017. p. 56. DOE/EE-1571; OSTI ID 1512366
- doi:10.1098/rspa.1954.0130 — Axial dispersion in turbulent pipe flow.
- doi:10.1021/ie4033999 — Thermophysical property library.