In short
It appears in fewer than 1 of every 100 lines studied.
When it appears, it takes on average about 53 % of the line's lost time. Reported by 0 of the 127 studies that could observe it (sparse evidence).
What happens
An operator sets a wrong parameter, mis-calibrates a sensor or instrument, or performs an incorrect manual action during operation, causing the equipment to stop, trip or run out of tolerance until the error is detected and corrected. The event is driven by human judgement or skill variability rather than by a component fault.
What is done about it
Standardize operating and calibration procedures, add poka-yoke or interlocks that prevent invalid parameter entry, and reinforce operator training and periodic competency checks on critical settings and instruments.
Practical guidance written from engineering knowledge; it is not a statistical estimate.
1Probability and evidence
- Probability of presence
- 0.3% [0.1–1.0%]
- Expected share of lost time
- 0.2% [0.0–0.5%]
- Share of lost time when present
- 53% [41–64%]
- Studies / units
- 127 / 161
- Evidence grade
- D
Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.
2Probability by segment
- Dairy products0.4% [0.0–1.5%]13 studies
- Soft drinks, bottled water and juices0.4% [0.0–1.4%]26 studies
- Brewing, wine and spirits0.4% [0.0–1.5%]11 studies
- Bakery and pasta0.4% [0.0–1.4%]24 studies
- Meat, poultry and seafood0.4% [0.0–1.5%]9 studies
- Fruit and vegetable processing0.4% [0.0–1.5%]7 studies
- Grain and oilseed milling0.4% [0.0–1.7%]6 studies
- Sugar and confectionery0.4% [0.0–1.6%]9 studies
- Snacks, coffee, tea and other foods0.4% [0.0–1.5%]5 studies
- Animal feed and pet food0.4% [0.0–1.5%]7 studies
- Food manufacturing (unspecified or mixed)0.4% [0.0–1.4%]10 studies
3Mechanism, SCADA signature and countermeasure
Mechanism
Engineering guidanceAn operator sets a wrong parameter, mis-calibrates a sensor or instrument, or performs an incorrect manual action during operation, causing the equipment to stop, trip or run out of tolerance until the error is detected and corrected. The event is driven by human judgement or skill variability rather than by a component fault.
How it looks in SCADA data
Engineering guidanceShort unplanned stop or alarm with no associated maintenance work order, often preceded by a manual parameter change, mode switch or operator intervention logged in the event history; the machine resumes quickly once the operator corrects the setting, and no recurring fault code points to a specific component.
Countermeasure
Engineering guidanceStandardize operating and calibration procedures, add poka-yoke or interlocks that prevent invalid parameter entry, and reinforce operator training and periodic competency checks on critical settings and instruments.
4Sources
- Enhancing Machinery Availability in a Food Company: An Integrated Approach Using TPM, SMED, and RCM Methodologies (2024)Open sourceShare of loss events: 8.47 % · as reported: “Breakdowns due to human errors in calibration or operation”
Show verbatim quote
Breakdowns due to human errors in calibration or operation | 8.47% | 38.38%
- Increase of the Availability of Machinery in a Food Company Applying the TPM, SMED and RCM Methodologies (2024)Open sourceShare of loss events: 8.47 % · as reported: “Breakdowns due to human errors in calibration or operation”
Show verbatim quote
Breakdowns due to human errors in calibration or operation 8.47%
- Propuesta de mejora para incrementar el rendimiento de la línea de salsas usando SMED, Kanban, Industria 4.0 y 5S en una empresa del sector alimenticio (2026)Open sourceShare of lost time: 4.21 % · as reported: “Errores humanos”
Show verbatim quote
Errores humanos 977.64 4.21% 94.34%
- Propuesta de mejora para incrementar el rendimiento de la línea de salsas usando SMED, Kanban, Industria 4.0 y 5S en una empresa del sector alimenticio (2026)Open sourceLost time: 978 min · as reported: “Errores humanos”
Show verbatim quote
Errores humanos 977.64 4.21% 94.34%
- Lost time: 6.00 min · as reported: “Erro humano”
Show verbatim quote
Erro humano 1 60 48,20 € 6
- Number of events: 1.00 events · as reported: “Erro humano”
Show verbatim quote
Erro humano 1 60 48,20 € 6