foratvise
Get Started
Idling and minor stops (micro-stops)

Unspecified minor stoppage on filling line

Idling and minor stops (micro-stops)PerformanceFilling

In short

It appears in about 1 of every 100 lines studied.

When it appears, it takes on average about 57 % of the line's lost time. Reported by 7 of the 120 studies that could observe it (good evidence).

What happens

The filler experiences brief interruptions arising from a variety of minor, uncatalogued disturbances (sensor blockages, small misfeeds, momentary jams, operator-cleared faults) that stop production without requiring maintenance intervention. Because the originating equipment or component is not identified in the source reports, these events are lumped together as a generic minor-stop category rather than a specific failure mode.

What is done about it

Perform a Pareto breakdown of micro-stop events by location and apparent trigger to reclassify the largest contributors into specific, actionable causes, and standardize operator clearing procedures to reduce recovery time. Where root causes remain diffuse, implement autonomous maintenance checks and sensor/guide adjustments on the filler to reduce the overall frequency of brief interruptions.

Practical guidance written from engineering knowledge; it is not a statistical estimate.

1Probability and evidence

Pooled over all segments. A wide interval is a result: it states how much the evidence allows us to know.
Probability of presence
1.5% [0.5–3.3%]
Expected share of lost time
0.8% [0.3–1.9%]
Share of lost time when present
57% [46–68%]
Studies / units
120 / 162
Evidence grade
B

Grade B: 5 to 9 studies, or an interval width between 0.20 and 0.35.

2Probability by segment

Partially pooled estimates for each industry segment.
  • Dairy products
    1.5% [0.3–4.4%]18 studies
  • Soft drinks, bottled water and juices
    1.8% [0.4–4.6%]44 studies
  • Brewing, wine and spirits
    1.4% [0.2–4.2%]16 studies
  • Bakery and pasta
    1.8% [0.3–6.1%]0 studies
  • Meat, poultry and seafood
    1.6% [0.3–5.1%]6 studies
  • Fruit and vegetable processing
    1.7% [0.3–5.5%]4 studies
  • Grain and oilseed milling
    1.6% [0.2–4.9%]6 studies
  • Sugar and confectionery
    1.7% [0.2–5.6%]3 studies
  • Snacks, coffee, tea and other foods
    2.3% [0.4–7.5%]6 studies
  • Animal feed and pet food
    1.7% [0.2–5.6%]4 studies
  • Food manufacturing (unspecified or mixed)
    3.1% [0.5–9.3%]13 studies

3Mechanism, SCADA signature and countermeasure

Engineering guidance that helps recognise and address the cause; it is not part of the statistical estimate.

Mechanism

Engineering guidance

The filler experiences brief interruptions arising from a variety of minor, uncatalogued disturbances (sensor blockages, small misfeeds, momentary jams, operator-cleared faults) that stop production without requiring maintenance intervention. Because the originating equipment or component is not identified in the source reports, these events are lumped together as a generic minor-stop category rather than a specific failure mode.

How it looks in SCADA data

Engineering guidance

MES/SCADA logs show numerous short machine-state transitions to a stopped or fault state on the filler, each below the minor-stop duration threshold, often without a specific alarm code or with a generic 'minor stop' tag. Event counters accumulate a high frequency of brief stops relative to longer downtime events, and no single recurring component signal dominates the pattern.

Countermeasure

Engineering guidance

Perform a Pareto breakdown of micro-stop events by location and apparent trigger to reclassify the largest contributors into specific, actionable causes, and standardize operator clearing procedures to reduce recovery time. Where root causes remain diffuse, implement autonomous maintenance checks and sensor/guide adjustments on the filler to reduce the overall frequency of brief interruptions.

4Sources

Every extracted datum with its study, value and verbatim quote.
  1. Share of lost time: 19.0 % · as reported: “operational stoppages”
    Show verbatim quote
    The next is 34% of cleaning inspection and lubrication process, 19% of operational stoppages, 3% of meals or break, 2% of change over time, and the last 1% of planned maintenance.
  2. Share of lost time: 67.0 % · as reported: “planned stoppages”
    Show verbatim quote
    Based on the whole company manufacturing process, the highest number of waiting waste occurs in filling machines, especially for the planned stoppages with 67% compared with the 33% for the unplanned stoppages.
  3. Share of lost time: 33.0 % · as reported: “unplanned stoppages”
    Show verbatim quote
    Based on the whole company manufacturing process, the highest number of waiting waste occurs in filling machines, especially for the planned stoppages with 67% compared with the 33% for the unplanned stoppages.
  4. Lost time: 524 min · as reported: “Idling & Minor Stoppages”
    Show verbatim quote
    Idling & Minor Stoppages 524 7,2 98,6
  5. Share of lost time: 7.20 % · as reported: “Idling & Minor Stoppages”
    Show verbatim quote
    Idling & Minor Stoppages 524 7,2 98,6
  6. Share of loss events: 15.9 % · as reported: “Idle and Minor Stoppage”
    Show verbatim quote
    Reduce Speed Losses with an average proportion of 3.82% and a relative frequency of 39.01%, Downtime Losses with an average of 2.27% and a relative frequency of 28.31%, Defect Losses with an average of 1.58% and a relative frequency of 15.59%, Idle and Minor Stoppage with an average of 1.55% and a relative frequency of 15.85%.
  7. Share of planned time: 1.55 % · as reported: “Idle and Minor Stoppage”
    Show verbatim quote
    Reduce Speed Losses with an average proportion of 3.82% and a relative frequency of 39.01%, Downtime Losses with an average of 2.27% and a relative frequency of 28.31%, Defect Losses with an average of 1.58% and a relative frequency of 15.59%, Idle and Minor Stoppage with an average of 1.55% and a relative frequency of 15.85%.
  8. Lost time: 0 mnt · as reported: “Minor Stoppages”
    Show verbatim quote
    3 Minor Stoppases 0 0 87
  9. Lost time: 0 mnt · as reported: “Minor Stoppages”
    Show verbatim quote
    3 Minor Stoppases 0 0 87
  10. Lost time: 87.0 mnt · as reported: “Minor Stoppages”
    Show verbatim quote
    3 Minor Stoppases 0 0 87
  11. Share of loss events: 6.67 % · as reported: “Major-Minor Stoppage (Mi)”
    Show verbatim quote
    กลุม Major-Minor Stoppage (Mi) ซึ่งเปนเหตุการณที่มีความรุนแรงหรือเปนปญหาเรื้อรัง มีจํานวนนอยที่สุดเพียง 163 ครั้ง หรือคิดเปนรอยละ 6.67
  12. Number of events: 163 events · as reported: “Major-Minor Stoppage (Mi)”
    Show verbatim quote
    กลุม Major-Minor Stoppage (Mi) ซึ่งเปนเหตุการณที่มีความรุนแรงหรือเปนปญหาเรื้อรัง มีจํานวนนอยที่สุดเพียง 163 ครั้ง หรือคิดเปนรอยละ 6.67
  13. Number of events: 1,535 events · as reported: “General-Minor Stoppage (GM)”
    Show verbatim quote
    พบวาเหตุการณการหยุดชะงักชั่วคราวของเครื่องจักรในระยะสั้นสวนใหญจัดอยูในกลุม General-Minor Stoppage (GM) มีจํานวนสูงสุดถึง 1,535 ครั้ง คิดเปนรอยละ 62.83 ของขอมูลทั้งหมด
  14. Share of loss events: 62.8 % · as reported: “General-Minor Stoppage (GM)”
    Show verbatim quote
    พบวาเหตุการณการหยุดชะงักชั่วคราวของเครื่องจักรในระยะสั้นสวนใหญจัดอยูในกลุม General-Minor Stoppage (GM) มีจํานวนสูงสุดถึง 1,535 ครั้ง คิดเปนรอยละ 62.83 ของขอมูลทั้งหมด
  15. Number of events: 745 events · as reported: “Non-Minor Stoppage (X)”
    Show verbatim quote
    รองลงมาคือ กลุม Non-Minor Stoppage (X) จํานวน 745 ครั้ง คิดเปนรอยละ 30.50
  16. Share of loss events: 30.5 % · as reported: “Non-Minor Stoppage (X)”
    Show verbatim quote
    รองลงมาคือ กลุม Non-Minor Stoppage (X) จํานวน 745 ครั้ง คิดเปนรอยละ 30.50