Included study
Integrating SMED and Mechanical Design for Changeover Reduction in Beverage Packaging Lines
1Bibliographic record
- Authors
- António Rocha Esteves
- Year
- 2026
- Venue
- Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT)
- DOI
- —
- Country
- Portugal
- Segment
- Brewing, wine and spirits
- Process family
- Filling and packaging line
- Study type
- Before/after intervention
- Extraction scope
- Full text
- Size
- 1 plants · 4 lines · 2 machines
- Observation period
- 731 days
- Data collection
- manual_logs
- Intervention
Show the setting as described by the study
This dissertation, developed at the Super Bock Group's plant in Leça do Balio, addresses these losses on the Kisters and Mead secondary-packaging machines by combining the Single-Minute Exchange of Die (SMED) methodology with formal machine design
2Risk of bias
Scored with the rubric of the protocol: 2 low concern, 1 some concerns, 0 high concern.
Total score 12Moderate risk
| Item | Score |
|---|---|
| Is the observed line, machine or plant described well enough to classify its segment, process and equipment?Product, process and equipment are all described. | 2 / 2 |
| Is the observation period long enough and reported?Period reported and at least 30 days of production (or at least 100 recorded events). | 2 / 2 |
| How were loss data collected?Manual logs or maintenance records with unknown completeness. | 1 / 2 |
| Are OEE, loading time and the loss categories defined explicitly?A standard definition is cited but its application is not shown. | 1 / 2 |
| Does the loss breakdown account for the total loss it claims to explain?The reported causes or categories sum to at least 90% of the stated total, or an explicit "other" class closes the balance. | 2 / 2 |
| Is there evidence of selective reporting of favourable results?Intervention study in which baseline and post-intervention periods differ in length or method. | 1 / 2 |
| Are the reported numbers internally consistent?Recomputed totals, shares and OEE factors agree with the reported values within 2 percentage points. | 2 / 2 |
| Could conflicts of interest or the source of the data bias the result?Authors are employees of the plant or of an equipment/software vendor; no declaration. | 1 / 2 |
3Extracted data
Each datum with its classification and the verbatim quote that states it.
| Reported cause | Loss category | Metric | Value | Extraction |
|---|---|---|---|---|
—Show verbatim quote (Section 1.1, Figure 1.2)during 2025 production (annual OEE averaged 61.63%) | none | OEE | 61.6 % | Both extractors agreed |
—Show verbatim quote (Section 1.1, Figure 1.1)with an overall average of 58.8% (Figure 1.1) | none | OEE | 58.8 % | Both extractors agreed |
proactive retrieval of Format PartsKistersShow verbatim quote (Table 6.2)Line 6 8 1.0/1.5 0.0 1.0/1.5 | Setup and adjustments | Lost time | 0 min | Both extractors agreed |
Breakdowns and Malfunctions Time (BMT)Show verbatim quote (Section 1.2)Although breakdown and malfunction losses (18.04%) are greater in aggregate than changeover and ramp-up losses (≈7.2%), they are not the focus of this study. | Equipment failure (breakdowns) | Share of planned time | 18.0 % | Single extractor |
Changeover Time (COT) and Ramp-Up Time (RUT)Show verbatim quote (Section 1.2)Although breakdown and malfunction losses (18.04%) are greater in aggregate than changeover and ramp-up losses (≈7.2%), they are not the focus of this study. | Setup and adjustments | Share of planned time | 7.20 % | Single extractor |
proactive retrieval of Format PartsKistersShow verbatim quote (Table 6.2)Line 1 6 0.5 0.0 0.5 | Setup and adjustments | Lost time | 0.500 min | Single extractor |
proactive retrieval of Format PartsKistersShow verbatim quote (Table 6.2)Line 1 6 0.5 0.0 0.5 | Setup and adjustments | Lost time | 0 min | Single extractor |
proactive retrieval of Format PartsKistersShow verbatim quote (Table 6.2)Line 2 6 1.0 0.0 1.0 | Setup and adjustments | Lost time | 1.00 min | Single extractor |
proactive retrieval of Format PartsKistersShow verbatim quote (Table 6.2)Line 2 6 1.0 0.0 1.0 | Setup and adjustments | Lost time | 0 min | Single extractor |
proactive retrieval of Format PartsKistersShow verbatim quote (Table 6.2)Line 5 10 1.0 0.0 1.0 | Setup and adjustments | Lost time | 1.00 min | Single extractor |
proactive retrieval of Format PartsKistersShow verbatim quote (Table 6.2)Line 5 10 1.0 0.0 1.0 | Setup and adjustments | Lost time | 0 min | Single extractor |
proactive retrieval of Format PartsKistersShow verbatim quote (Table 6.2)Line 6 8 1.0/1.5 0.0 1.0/1.5 | Setup and adjustments | Lost time | 1.00 min | Single extractor |
Type A changeoverKistersShow verbatim quote (Table 6.4)Type A 30.0, 33.0 (µ = 31.5) 24.0, 26.0 (µ = 25.0) 6.5 min 20.6% | Setup and adjustments | Mean event duration | 31.5 min | Single extractor |
Type B changeoverKistersShow verbatim quote (Table 6.4)Type B 35.0, 28.0 (µ = 31.5) 26.0, 27.0 (µ = 26.5) 5.0 min 15.9% | Setup and adjustments | Mean event duration | 31.5 min | Single extractor |
Type C changeoverKistersShow verbatim quote (Table 6.4)Type C 38.0, 49.0 (µ = 43.5) 35.0, 37.0 (µ = 37.5) 6.0 min 13.8% | Setup and adjustments | Mean event duration | 43.5 min | Single extractor |
Type D changeoverKistersShow verbatim quote (Table 6.4)Type D 39.0, 39.0, 48.0 (µ = 42.0) 35.0, 35.0 (µ = 35.0) 7.0 min 16.7% | Setup and adjustments | Mean event duration | 42.0 min | Single extractor |
pooled all changeover types (A, B, C, D)KistersShow verbatim quote (Section 6.4.2)The pooled analysis shows a mean reduction from 37.7 to 30.6 minutes (18.7%), with a large effect size (Hedges’ g = 1.04). | Setup and adjustments | Mean event duration | 37.7 min | Single extractor |
Type A changeoverKistersShow verbatim quote (Table 6.4)Type A 30.0, 33.0 (µ = 31.5) 24.0, 26.0 (µ = 25.0) 6.5 min 20.6% | Setup and adjustments | Mean event duration | 25.0 min | Single extractor |
Type B changeoverKistersShow verbatim quote (Table 6.4)Type B 35.0, 28.0 (µ = 31.5) 26.0, 27.0 (µ = 26.5) 5.0 min 15.9% | Setup and adjustments | Mean event duration | 26.5 min | Single extractor |
Type C changeoverKistersShow verbatim quote (Table 6.4)Type C 38.0, 49.0 (µ = 43.5) 35.0, 37.0 (µ = 37.5) 6.0 min 13.8% | Setup and adjustments | Mean event duration | 37.5 min | Single extractor |
Type D changeoverKistersShow verbatim quote (Table 6.4)Type D 39.0, 39.0, 48.0 (µ = 42.0) 35.0, 35.0 (µ = 35.0) 7.0 min 16.7% | Setup and adjustments | Mean event duration | 35.0 min | Single extractor |
pooled all changeover types (A, B, C, D)KistersShow verbatim quote (Section 6.4.2)The pooled analysis shows a mean reduction from 37.7 to 30.6 minutes (18.7%), with a large effect size (Hedges’ g = 1.04). | Setup and adjustments | Mean event duration | 30.6 min | Single extractor |
Cardboard Module tuning stoppagesCardboard Cutout Feeding ModuleShow verbatim quote (Section 7.2, Figure 7.3)Among the 29 changeovers interrupted for these reasons, 24 experienced multiple stoppages. | Setup and adjustments | Number of events | 29.0 changeovers | Single extractor |
Cardboard Module tuning stoppages (multiple stoppages)Cardboard Cutout Feeding ModuleShow verbatim quote (Section 7.2, Figure 7.3)Among the 29 changeovers interrupted for these reasons, 24 experienced multiple stoppages. | Setup and adjustments | Number of events | 24.0 changeovers | Single extractor |
Cardboard Module fine-tuning (single stoppage)Cardboard Cutout Feeding ModuleShow verbatim quote (Section 7.2, Figure 7.4)The median fine-tuning duration is 6 minutes for changeovers with a single stoppage, rising to 14 minutes for changeovers with two or more stoppages. | Setup and adjustments | Mean event duration | 6.00 min | Single extractor |
Cardboard Module fine-tuning (two or more stoppages)Cardboard Cutout Feeding ModuleShow verbatim quote (Section 7.2, Figure 7.4)The median fine-tuning duration is 6 minutes for changeovers with a single stoppage, rising to 14 minutes for changeovers with two or more stoppages. | Setup and adjustments | Mean event duration | 14.0 min | Single extractor |
Folding Bracket Assembly Task (Redesigned Component)Kisters Folding Bracket ModuleShow verbatim quote (Abstract, page ii)A redesigned tool-less folding bracket reduced its adjustment task time by 78.5% and its variance by 99.3% under statistically conclusive testing. | Setup and adjustments | Mean event duration | 78.5 % reduction | Single extractor |
Observation units
- Lines 1, 2, 5 and 6 (whole plant, SBG Leça do Balio) · Whole line or unspecified equipment · Baseline
- Kisters - Line 6 (Format Parts Retrieval task) · Packaging (forming, sealing, wrapping, case packing, palletizing) · After intervention
- Kisters - Line 1 (Format Parts Retrieval task) · Packaging (forming, sealing, wrapping, case packing, palletizing) · Baseline
- Kisters - Line 1 (Format Parts Retrieval task) · Packaging (forming, sealing, wrapping, case packing, palletizing) · After intervention
- Kisters - Line 2 (Format Parts Retrieval task) · Packaging (forming, sealing, wrapping, case packing, palletizing) · Baseline
- Kisters - Line 2 (Format Parts Retrieval task) · Packaging (forming, sealing, wrapping, case packing, palletizing) · After intervention
- Kisters - Line 5 (Format Parts Retrieval task) · Packaging (forming, sealing, wrapping, case packing, palletizing) · Baseline
- Kisters - Line 5 (Format Parts Retrieval task) · Packaging (forming, sealing, wrapping, case packing, palletizing) · After intervention
- Kisters - Line 6 (Format Parts Retrieval task) · Packaging (forming, sealing, wrapping, case packing, palletizing) · Baseline
- Kisters - Line 1 (Adjustment Values / Slider Optimisation) · Packaging (forming, sealing, wrapping, case packing, palletizing) · Baseline
- Kisters - Line 1 (Adjustment Values / Slider Optimisation) · Packaging (forming, sealing, wrapping, case packing, palletizing) · After intervention
- Kisters - Cardboard Cutout Feeding Module (observed changeovers, Feb-May 2026, all lines) · Packaging (forming, sealing, wrapping, case packing, palletizing) · Baseline
- Line 1 Kisters · Packaging (forming, sealing, wrapping, case packing, palletizing) · After intervention