Mechanical, electrical or pneumatic component failure
In short
It appears in about 1 of every 100 lines studied.
When it appears, it takes on average about 59 % of the line's lost time. Reported by 5 of the 127 studies that could observe it (good evidence).
What happens
Wear, fatigue, misalignment, corrosion or electrical/pneumatic component degradation accumulates in drives, bearings, actuators, sensors, valves, wiring or control hardware until the part can no longer perform its function, forcing the line or a machine to stop until repaired. Because the failing component is not specified, the loss aggregates any breakdown of mechanical, electrical or pneumatic nature across the line rather than a single identifiable failure mode.
What is done about it
Apply condition-based and preventive maintenance with vibration, current and pressure monitoring on critical mechanical, electrical and pneumatic assets, keep critical spares available, and use root-cause/failure-mode analysis on recurring breakdowns to redesign weak components or revise maintenance intervals.
Practical guidance written from engineering knowledge; it is not a statistical estimate.
1Probability and evidence
- Probability of presence
- 1.4% [0.5–3.2%]
- Expected share of lost time
- 0.9% [0.3–1.9%]
- Share of lost time when present
- 59% [49–69%]
- Studies / units
- 127 / 161
- Evidence grade
- B
Grade B: 5 to 9 studies, or an interval width between 0.20 and 0.35.
2Probability by segment
- Dairy products1.5% [0.2–4.9%]13 studies
- Soft drinks, bottled water and juices1.7% [0.4–4.8%]26 studies
- Brewing, wine and spirits1.5% [0.2–4.9%]11 studies
- Bakery and pasta3.1% [0.7–8.3%]24 studies
- Meat, poultry and seafood1.5% [0.2–4.7%]9 studies
- Fruit and vegetable processing1.6% [0.2–5.2%]7 studies
- Grain and oilseed milling2.4% [0.4–7.7%]6 studies
- Sugar and confectionery1.5% [0.2–5.0%]9 studies
- Snacks, coffee, tea and other foods1.6% [0.3–4.9%]5 studies
- Animal feed and pet food1.6% [0.2–5.2%]7 studies
- Food manufacturing (unspecified or mixed)1.6% [0.2–4.8%]10 studies
3Mechanism, SCADA signature and countermeasure
Mechanism
Engineering guidanceWear, fatigue, misalignment, corrosion or electrical/pneumatic component degradation accumulates in drives, bearings, actuators, sensors, valves, wiring or control hardware until the part can no longer perform its function, forcing the line or a machine to stop until repaired. Because the failing component is not specified, the loss aggregates any breakdown of mechanical, electrical or pneumatic nature across the line rather than a single identifiable failure mode.
How it looks in SCADA data
Engineering guidanceSCADA/MES logs show unplanned machine-down states with maintenance-coded stop reasons, fault or alarm codes from drives, motors, PLC I/O or pneumatic pressure switches, and a sudden drop to zero in actual speed or output counters that persists until a maintenance intervention is logged. Repeated short-interval alarms from the same tag before the final stop can indicate progressive degradation.
Countermeasure
Engineering guidanceApply condition-based and preventive maintenance with vibration, current and pressure monitoring on critical mechanical, electrical and pneumatic assets, keep critical spares available, and use root-cause/failure-mode analysis on recurring breakdowns to redesign weak components or revise maintenance intervals.
4Sources
- Reliability-Centered Maintenance Model to Improve OEE in a Mass-Consumption Food Company: A Case Study from Peru (2025)Open sourceShare of lost time: 30.2 % · as reported: “mechanical and electrical failures”
Show verbatim quote
These reasons were linked to specific root causes: mechanical and electrical failures explained 30.2% of the stoppages, while instrumentation faults represented 19%.
- Innovation in Smart Maintenance: An IoT-Based Strategy to Improve Packaging Machine Availability in a SME (2025)Open sourceShare of planned time: 7.65 % · as reported: “recurrent failures in mechanical and pneumatic components”
Show verbatim quote
High downtime rate due to recurrent failures in mechanical and pneumatic components 7.65% 1.03% 2.06%
- Share of lost time: 50.0 % · as reported: “equipment mechanical issues”
Show verbatim quote
60% of work time produced results but 30% was lost because materials needed to wait for 40% of the time and 10% stemmed from machine downtime where 50% resulted from equipment mechanical issues.
- Propuesta para incrementar la disponibilidad de equipos a través de la implementación de Lean Manufacturing e IoT en una industria de galletas (2025)Open sourceLost time: 11,990 min · as reported: “fallas mecánicas, eléctricas y fallas operacionales”
Show verbatim quote
Los motivos principales son las fallas mecánicas, eléctricas, y las fallas operacionales, las cuales generaron 11990 minutos de detención en el año 2024 según se presenta en la tabla 7
- Propuesta para incrementar la disponibilidad de equipos a través de la implementación de Lean Manufacturing e IoT en una industria de galletas (2025)Open sourceLost time: 7,039 min · as reported: “Falla Mecánica y eléctrica”
Show verbatim quote
Falla Mecánica y eléctrica 7039 24.300% S/336,117.47
- Propuesta para incrementar la disponibilidad de equipos a través de la implementación de Lean Manufacturing e IoT en una industria de galletas (2025)Open sourceShare of lost time: 24.3 % · as reported: “Falla Mecánica y eléctrica”
Show verbatim quote
Falla Mecánica y eléctrica 7039 24.300% S/336,117.47
- Productivity Improvement Through the Application of Lean Six Sigma Tools in a Non-Alcoholic Beverage Company (2025)Open sourceLost time: 1,120 min/year · as reported: “mechanical failures”
Show verbatim quote
16,800 minutes/year lost to changeover times (setup), 1,120 minutes/year due to mechanical failures, 42,336 defective units/year, and 17,472 minutes/year spent searching for tools.
- Productivity Improvement in a Bakery and Pastry Premix Company by Applying Preventive Maintenance, SMED and 5´S (2026)Open sourceNumber of events: 7.00 failures/month · as reported: “mechanical failures”
Show verbatim quote
the number of mechanical failures, which averaged 7 per month, was reduced to 1 failure per machine
- APLICAÇÃO DO INDICADOR OVERALL EQUIPMENT EFFECTIVENESS (OEE) EM INDÚSTRIA DE CARNES E DERIVADOS (2023)Open sourceShare of loss events: 50.0 % · as reported: “falha elétrica”
Show verbatim quote
os fatores causadores de perdas com maior impacto na produtividade foram a ocorrência de falha elétrica, seguido da ocorrência de falha mecânica nas máquinas, sendo estes os motivos correspondentes a mais de 50% das ocorrências
- APLICAÇÃO DO INDICADOR OVERALL EQUIPMENT EFFECTIVENESS (OEE) EM INDÚSTRIA DE CARNES E DERIVADOS (2023)Open sourceShare of loss events: 50.0 % · as reported: “falha mecânica”
Show verbatim quote
os fatores causadores de perdas com maior impacto na produtividade foram a ocorrência de falha elétrica, seguido da ocorrência de falha mecânica nas máquinas, sendo estes os motivos correspondentes a mais de 50% das ocorrências