foratvise
Get Started
Filling and packaging line

Labeling and coding

Roll-fed wrap-around labelling of cylindrical containers with hot-melt glue

Validated modelOEE bound 1.000 [0.775–1.000]20,000 Monte Carlo samples · seed 20261115 · computed November 16, 2026

In short

Labeling and coding can use at most 100 of every 100 planned hours. The rest goes to limits no plant can avoid.

  1. 100usable at most

The three limits that set it

Running time: up to 100 %

The rest are stops imposed by physics or by regulation: cleaning, changeovers, defrosting.

Speed: up to 100 %

How close to its maximum speed it can run without damaging the product or the equipment.

Good product: up to 100 %

Some product falls outside specification even with the process well under control.

See the technical detail

Technical detail

Uncertainty intervals, physical models per station and sources, for anyone who wants to check each figure.

1Scenario

Filled and capped 0.5 L PET bottles of a carbonated soft drink are labelled downstream of the filler on a rotary roll-fed labeller. The label web is drawn from a reel, each label is cut to length at the print mark, receives hot-melt glue on its leading and trailing edges and is wrapped once around the cylindrical label panel of the rotating container; the trailing edge is glued over the leading edge. The same geometry describes wrap-around paper labels on cans of vegetables. The physics-limited quantities are the overlap of the glue seam (geometry and cutting registration) and the web speed at which the registration still keeps the seam capable. The labeller runs faster than the filler (the V-graph of a bottling line); its documented set performance and failure behaviour come from measurements in an industrial bottling plant.

Provenance of inputsDeclared assumption21Verified quote5

2Results

Point value from the nominal parameters and 95% interval from 20,000 Monte Carlo draws of the uncertain parameters.
  • Cut length of the label (panel circumference plus nominal overlap)212 [203–221] mm
  • Standard deviation of the overlap at standstill registration (cutting and container diameter only)0.434 [0.295–0.580] mm
  • Largest web speed at which the overlap stays z standard deviations above its minimum3.00 [2.04–3.93] m/s
  • Standard deviation of the overlap at the capable web speed0.741 [0.419–1.332] mm
  • Share of labels whose overlap is shorter than the minimum glue seam6.20 × 10⁻¹⁰ [6.25 × 10⁻³⁰–4.39 × 10⁻⁴]
  • Share of labels placed outside the vertical tolerance of the label panel5.73 × 10⁻⁷ [1.44 × 10⁻¹⁶–1.79 × 10⁻²]
  • TheoreticalMaximum OEE quality factor (overlap seam and placement) at the capable web speed1.000 [0.982–1.000]
  • Quality factor if the labeller ran at its maximum web speed regardless of registration capability1.000 [0.982–1.000]
  • Containers per hour at the maximum web speed of the declared machine50,895 [34,701–67,675] 1/h
  • Containers per hour at the capable web speed50,895 [34,561–67,168] 1/h
  • Best documentedSet performance of a labelling machine measured in an industrial bottling plant33,197 1/h
  • TheoreticalThermodynamic minimum energy per label (the glue returns to ambient)0 J
  • Heat to bring the glue of one label to the application temperature, without recovery5.70 [3.38–14.39] J
  • Glue heating duty per kg of labelled product0.0110 [0.0065–0.0277] kJ/kg
  • Run time of one label reel at the capable rate22.2 [10.6–41.8] min
  • TheoreticalMaximum label-material yield (splice and start-up waste)0.9994 [0.9980–0.9997]
  • TheoreticalMaximum availability (no stop is forced by physics or regulation: reel changes are removable by an automatic splicer)1.00
  • Best documentedAvailability of a labelling machine from its measured MTBF and MTTR0.973
  • Availability with declared manual reel splices0.881 [0.705–0.960]
  • TheoreticalPerformance factor: capable web speed over maximum web speed1.00 [0.78–1.00]
  • TheoreticalPhysics-bounded OEE1.000 [0.775–1.000]
  • OEE with declared manual reel splices0.881 [0.643–0.958]

3Ceilings per dimension

Each dimension shows the ceilings the model computes and, where units are comparable, documented benchmarks. Colour and marker shape identify the ceiling type throughout the Oracle.
  • Theoretical
  • Best available technique
  • Best documented
  • Typical
Qualityhigher is better
  • TheoreticalMaximum OEE quality factor (overlap seam and placement) at the capable web speed1.000 [0.982–1.000]
Throughput1/h · higher is better
  • Best documentedSet performance of a labelling machine measured in an industrial bottling plant33,197 1/h
Energy per unit of productJ · lower is better
  • TheoreticalThermodynamic minimum energy per label (the glue returns to ambient)0 J
Yieldhigher is better
  • TheoreticalMaximum label-material yield (splice and start-up waste)0.9994 [0.9980–0.9997]
Availabilityhigher is better
  • TheoreticalMaximum availability (no stop is forced by physics or regulation: reel changes are removable by an automatic splicer)1.00
  • Best documentedAvailability of a labelling machine from its measured MTBF and MTTR0.973
Performancehigher is better
  • TheoreticalPerformance factor: capable web speed over maximum web speed1.00 [0.78–1.00]
OEEhigher is better
  • TheoreticalPhysics-bounded OEE1.000 [0.775–1.000]

4Loss cascade

What separates each ceiling from the next one, from the physical limit to typical operation.
  1. TheoreticalBest documentedAvailability
    1.00 → 0.973 (gap 0.0273)

    No stop of a roll-fed labeller is forced by physics or by regulation: the reel change is removable by an automatic splicer and there is no hygienic cleaning duty on the label path, so the availability ceiling is 1. The documented labeller of an industrial bottling plant stopped on average every 1 423 s for 40 s, an availability of 97.3 %. Such short, frequent stops are typical of container handling: containers that jam in the infeed star wheel or the centring bells, labels that fail to transfer from the vacuum or glue pallet, glue that strings or chars, and sensor faults at the print mark. Each of these is a mechanical or control loss, not a physical limit; in a line, an accumulation conveyor between filler and labeller absorbs most of them (see the conveying model).

  2. TheoreticalTypicalEnergy per unit of product

    The glue is heated and cools back to ambient on the container, so with ideal heat recovery no net energy would be needed: the thermodynamic minimum is zero. Without recovery the least heat is that of bringing the few tens of milligrams of glue per label to the application temperature, a few joules per label and a few thousandths of a kilojoule per kilogram of product. A real glue station keeps a melt tank, hoses and a glue roller at temperature all the time and loses heat continuously to the room, and the drives of the turret, the vacuum drum and the conveyors dominate the electricity of the machine; the energy of labelling is set by machinery, not by the physics of the label.

5Physics-bounded OEE

The highest OEE the operation can reach: availability, performance and quality limited only by unavoidable stops and physical capability.
Fraction of loading time that remains after each unavoidable loss. Axis starts at 0.70.
  • Loading time (ideal)
    1.000
  • Availability
    factor 1.00
    1.000 (−0.000)
  • Performance
    factor 1.00 [0.78–1.00]
    1.000 (−0.000)
  • Quality
    factor 1.000 [0.982–1.000]
    1.000 (−0.000)
  • Physics-bounded OEE
    1.000 [0.775–1.000]

6Full derivation

Mass and energy balances, rate-limiting step, process capability and unavoidable stops, with every term explained.

Scope. Filled and capped 0.5 L PET bottles of a carbonated soft drink are labelled downstream of the filler on a rotary roll-fed labeller. Each label is cut from the web at its print mark, receives hot-melt glue on its leading and trailing edges and is wrapped once around the cylindrical label panel of the rotating bottle; the trailing edge is glued over the leading edge. The same geometry describes wrap-around paper labels on cans of vegetables. The labeller runs faster than the filler (the V-graph of a bottling line). Symbols and their values, units, uncertainty distributions and sources are listed in the parameter table generated from config/physics/labeling.yaml. Numbers quoted here are point values; the output table gives the Monte Carlo intervals.

1. Mass balance — maximum label-material yield

Labelling consumes no product. Label web is lost at each reel splice (a length LwL_w around the splice) and at each changeover while the cut registration settles (nsun_{su} labels). During a campaign of duration tcampt_{camp} at the capable rate n˙cap\dot n_{cap} the web used for good labels is Lcamp=n˙cap tcamp LL_{camp} = \dot n_{cap}\,t_{camp}\,L, the number of reels is nr=Lcamp/Lrn_r = L_{camp}/L_r, and

Ymax=LcampLcamp+nrLw+nsuL=0.9994,Y_{max} = \frac{L_{camp}}{L_{camp} + n_r L_w + n_{su} L} = 0.9994,

where LL is the cut length of one label. A container rejected for a bad label is counted as a quality loss (section 4), not as a yield loss: the product and the container are not consumed by the labeller.

2. Energy balance — minimum energy per label

The glue is melted, applied and cools back to ambient on the container; the label and the container end in their initial thermal state. In the reversible limit all the heat could be recovered, so the thermodynamic minimum is zero. Without recovery the least heat is that of bringing the glue mass mgm_g of one label from ambient T0T_0 to the application temperature TgT_g:

Qglue=mg cp,g (Tg−T0)=5.7 J per label,Q_{glue} = m_g\,c_{p,g}\,(T_g - T_0) = 5.7\ \text{J per label},

0.011 kJ per kg of product. Glue mass, specific heat and temperature are declared scenario values. A real glue station keeps a melt tank, hoses and a glue roller hot all the time and loses heat continuously; the turret, vacuum drum and conveyor drives dominate the electricity of the machine.

3. Rate-limiting step — web speed and registration

Label length. A label wraps the panel of diameter DD once and overlaps itself by the nominal overlap ono_n:

L=πD+on=212.2 mm.L = \pi D + o_n = 212.2\ \text{mm}.

Rate. The web feeds one label length per container, so the rate at web speed vv is n˙=v/L\dot n = v/L: 50 900 containers per hour at the maximum web speed of the declared machine, vmaxv_{max} = 3 m/s. The web speed is a machine design value without an open source, so the rates carry no theoretical label (assumption a3).

Registration error grows with speed. The cut is triggered at the print mark. A timing error δt\delta t of mark detection and cut actuation becomes a length error v δtv\,\delta t, so the standard deviation of the cut length is

σL(v)2=σL,02+(v σt)2,\sigma_L(v)^2 = \sigma_{L,0}^2 + (v\,\sigma_t)^2,

where σL,0\sigma_{L,0} is the error of the cutting mechanism at standstill registration and σt\sigma_t the timing jitter. The faster the web, the wider the scatter of the overlap; this is the physical trade-off between speed and quality of the operation.

Capable web speed. The realised overlap is o=Lcut−πDco = L_{cut} - \pi D_c (section 4); with independent cut length and container diameter its standard deviation is

σo(v)=σL(v)2+(πσD)2.\sigma_o(v) = \sqrt{\sigma_L(v)^2 + (\pi\sigma_D)^2}.

A capable process keeps the mean overlap zz standard deviations above the minimum glue seam omino_{min}, i.e. σo(v)≤(on−omin)/z\sigma_o(v) \le (o_n - o_{min})/z. The largest capable web speed is

vcap=min⁡ ⁣(vmax, 1σt(on−ominz)2−σL,02−(πσD)2).v_{cap} = \min\!\left(v_{max},\ \frac{1}{\sigma_t}\sqrt{\left(\frac{o_n - o_{min}}{z}\right)^2 - \sigma_{L,0}^2 - (\pi\sigma_D)^2}\right).

With the declared values the registration limit is 6.0 m/s, above the machine's 3 m/s, so vcap=vmaxv_{cap} = v_{max}; when the jitter is large (upper part of its range) the capable speed falls below the maximum and the performance factor drops below 1.

4. Process capability — quality ceiling

Overlap seam. The trailing-edge glue bead must land on the label itself; if the overlap is shorter than omino_{min} the seam carries only part of the bead and the label opens or flags. With o∼N(on,σo2)o \sim \mathcal N(o_n, \sigma_o^2) the share of short seams is

u=Φ ⁣(omin−onσo(vcap))=6×10−10,u = \Phi\!\left(\frac{o_{min} - o_n}{\sigma_o(v_{cap})}\right) = 6\times10^{-10},

with σo(vcap)\sigma_o(v_{cap}) = 0.74 mm and Φ\Phi the standard normal distribution function.

Vertical placement. The label must stay within ±Δv\pm\Delta_v of its nominal height on the panel; with a vertical position error e∼N(0,σv2)e \sim \mathcal N(0, \sigma_v^2) the misplaced share is m=2 Φ(−Δv/σv)=5.7×10−7m = 2\,\Phi(-\Delta_v/\sigma_v) = 5.7\times10^{-7}.

Qmax=(1−u)(1−m)=0.999999.Q_{max} = (1 - u)(1 - m) = 0.999999 .

Running at the maximum web speed regardless of registration capability gives quality_at_max_speed, which equals QmaxQ_{max} here because the declared machine is capable at full speed. Wrinkles, flags caused by the glue, print defects and code legibility are not modelled, so QmaxQ_{max} is an upper bound. No open source quotes the minimum glue overlap, the cutting accuracy, the timing jitter or the placement tolerance of roll-fed labellers; they are declared scenario values with ranges, and the Monte Carlo interval of QmaxQ_{max} reflects them.

5. Unavoidable stops — maximum availability

A reel holds a finite web length and runs out after Lr/(n˙capL)L_r/(\dot n_{cap} L) = 22 minutes at the capable rate. A manual splice stops the labeller, but an automatic splicer removes the stop (not the splice waste); no cleaning-in-place applies to the label path, so the cleaning model is not used. No stop is forced by physics or regulation:

Amax=1.A_{max} = 1 .

With manual splices of duration tspt_{sp},

Ascen=tcamptcamp+nr tsp=0.881,A_{scen} = \frac{t_{camp}}{t_{camp} + n_r\,t_{sp}} = 0.881,

which enters only oee_scenario.

Documented availability. In an industrial bottling plant (mineral water and soft drinks, returnable glass bottles), the labelling machine was measured at a set performance of 33 197 bottles per hour with a mean time between failures of 1 423 s and a mean time to repair of 40 s (Bär et al., 2021, Table A1). With the availability defined in the same source as A=MTBF/(MTBF+MTTR)A = MTBF/(MTBF + MTTR),

Adoc=14231423+40=0.9727,A_{doc} = \frac{1423}{1423 + 40} = 0.9727,

the 97.3 % of the source table. These short, frequent stops (jams in the star wheels, failed label transfers, glue and sensor faults) are mechanical and control losses, not physical limits; the conveying model shows how much of them an accumulation buffer keeps away from the filler.

6. Physics-bounded OEE

Scope of the bound. The theoretical label of OEEmaxOEE_{max} means physics-bounded under the declared scenario: the ceiling follows from the geometry and registration physics of the operation for the declared container, label and machine, and it is a bound only conditional on those declarations. It follows the common definition of all models: AmaxA_{max} counts only stops required by regulation or forced by a physical mechanism; PmaxP_{max} is the ratio of the physics-limited ideal cycle to the cycle of the capable process; QmaxQ_{max} is the share of conforming units, and mass losses of conforming material are reported only as yield.

OEEmax=Amax×Pmax×Qmax,Pmax=vcapvmax=1,OEEmax=0.999999.OEE_{max} = A_{max} \times P_{max} \times Q_{max}, \qquad P_{max} = \frac{v_{cap}}{v_{max}} = 1, \qquad OEE_{max} = 0.999999 .

The labeller does not bound the line by physics: its ceiling is set by the registration capability, which the declared machine meets at full speed. With the declared manual splices oee_scenario = 0.881; the documented failure behaviour of a real labeller gives an availability of 0.973.

Consistency with the other models. The labeller runs faster than the filler, so in a line it never sets the rate; its documented set performance (33 197 per hour against 28 998 per hour of the filler of the same plant, a table cell the filler shares with the empty bottle inspector) is the V-graph used in the conveying model. Filling, closing and the product are outside this model.

7. Assumptions and validity

See the assumption and validity lists generated from the configuration file. The most influential inputs (sensitivity table) are the timing jitter, the maximum web speed and the overlap margin for performance, the vertical placement dispersion for quality, and the reel length and splice time for the scenario availability.

References

  • Bär, R. M., Zeilmann, M., Nophut, C., Kleinert, J., Beyer, K., Voigt, T. (2021). Simulation of energy and media demand of beverage bottling plants by automatic model generation. Sustainability, 13, 10089. doi:10.3390/su131810089

7Parameters and provenance

Every input with its value, unit, role, uncertainty distribution and provenance. Open a quote to read the passage of the source that states the value.
  • DD65 mm

    Diameter of the cylindrical label panel of the container

    Scenario · Uniform 62 to 68 mm

    Declared assumption

    0.5 L PET bottle; no open bottle drawing was used. Declared assumption.

  • σD\sigma_D0.1 mm

    Standard deviation of the label-panel diameter from container to container

    Scenario · Uniform 0.05 to 0.15 mm

    Declared assumption
  • ono_n8 mm

    Nominal overlap of the trailing edge over the leading edge (label design)

    Scenario · Uniform 7 to 9 mm

    Declared assumption
  • omino_{min}3.5 mm

    Least overlap that still carries the full glue bead of the seam

    Scenario · Uniform 3 to 4 mm

    Declared assumption

    No open source states the minimum glue-seam overlap; declared assumption.

  • σL,0\sigma_{L,0}0.3 mm

    Standard deviation of the cut length from the cutting mechanism alone (standstill registration)

    Scenario · Uniform 0.2 to 0.4 mm

    Declared assumption
  • σt\sigma_t0.2 ms

    Timing jitter of print-mark detection and cut actuation

    Scenario · Uniform 0.05 to 0.4 ms

    Declared assumption

    A timing error becomes a length error v_web sigma_t; declared assumption.

  • zz3.5

    Capability margin of the overlap in standard deviations

    Scenario · Uniform 3 to 4

    Declared assumption

    Operating choice, point value at the centre of the declared range.

  • vmaxv_{max}3 m/s

    Maximum label-web speed of the declared labeller

    Scenario · Uniform 2 to 4 m/s

    Declared assumption

    Machine design value; no open source was used.

  • Δv\Delta_v1.5 mm

    Allowed vertical displacement of the label on the panel

    Scenario · Uniform 1 to 2 mm

    Declared assumption
  • σv\sigma_v0.3 mm

    Standard deviation of the vertical label position

    Scenario · Uniform 0.2 to 0.5 mm

    Declared assumption
  • TgT_g120 °C

    Application temperature of the hot-melt glue

    Scenario · Uniform 110 to 140 °C

    Declared assumption
  • T0T_025 °C

    Ambient temperature

    Scenario · Fixed

    Declared assumption
  • mgm_g30 mg

    Mass of hot-melt glue per label (pick-up and overlap beads)

    Scenario · Uniform 15 to 60 mg

    Declared assumption
  • cp,gc_{p,g}2 kJ/kg/K

    Specific heat of the hot-melt glue

    Scenario · Uniform 1.8 to 2.6 kJ/kg/K

    Declared assumption

    Typical of polymer melts; no open source was used. Declared assumption.

  • mpm_p0.52 kg

    Mass of product per container

    Scenario · Fixed

    Declared assumption

    0.5 L of a sweetened soft drink of density about 1040 kg/m3.

  • LrL_r4,000 m

    Label-web length on one reel

    Scenario · Uniform 2,000 to 6,000 m

    Declared assumption
  • LwL_w2 m

    Label web wasted at each reel splice

    Scenario · Uniform 1 to 5 m

    Declared assumption
  • nsun_{su}30

    Labels wasted while registration settles after a changeover

    Scenario · Uniform 10 to 60

    Declared assumption
  • tcampt_{camp}8 h

    Production time between two label changeovers

    Scenario · Uniform 4 to 24 h

    Declared assumption
  • tspt_{sp}3 min

    Machine stop per manual reel change and splice (zero with an automatic splicer)

    Scenario · Uniform 1 to 6 min

    Declared assumption
  • n˙doc\dot n_{doc}33,197 1/h

    Set performance of the labelling machine of an industrial bottling plant (glass bottles, wet-glue labels; measured)

    Benchmark · Fixed

    Verified quote
    Show verbatim quote
    Labelling machine 33,197 30 1423 40 97.3Simulation of Energy and Media Demand of Beverage Bottling Plants by Automatic Model Generation (Bär, R. M.; Zeilmann, M.; Nophut, C.; Kleinert, J.; Beyer, K.; Voigt, T.), Sustainability 13, 10089 (2021), CC BY 4.0 (opens in a new tab). MDPI (copy distributed by a co-author's institution), 2021. p. 18. doi:10.3390/su131810089
  • MTBFMTBF1,423 s

    Measured mean time between failures of the labelling machine

    Benchmark · Fixed

    Verified quote
    Show verbatim quote
    Labelling machine 33,197 30 1423 40 97.3Simulation of Energy and Media Demand of Beverage Bottling Plants by Automatic Model Generation (Bär, R. M.; Zeilmann, M.; Nophut, C.; Kleinert, J.; Beyer, K.; Voigt, T.), Sustainability 13, 10089 (2021), CC BY 4.0 (opens in a new tab). MDPI (copy distributed by a co-author's institution), 2021. p. 18. doi:10.3390/su131810089
  • MTTRMTTR40 s

    Measured mean time to repair of the labelling machine

    Benchmark · Fixed

    Verified quote
    Show verbatim quote
    Labelling machine 33,197 30 1423 40 97.3Simulation of Energy and Media Demand of Beverage Bottling Plants by Automatic Model Generation (Bär, R. M.; Zeilmann, M.; Nophut, C.; Kleinert, J.; Beyer, K.; Voigt, T.), Sustainability 13, 10089 (2021), CC BY 4.0 (opens in a new tab). MDPI (copy distributed by a co-author's institution), 2021. p. 18. doi:10.3390/su131810089

8Benchmarks

Documented values from open sources used to check the ceilings; no documented value may beat the theoretical limit.
BenchmarkCeilingValueProvenance
Availability of the labelling machine of an industrial bottling plant, measured (MTBF / (MTBF + MTTR))
Show verbatim quote
Labelling machine 33,197 30 1423 40 97.3Simulation of Energy and Media Demand of Beverage Bottling Plants by Automatic Model Generation (Bär, R. M.; Zeilmann, M.; Nophut, C.; Kleinert, J.; Beyer, K.; Voigt, T.), Sustainability 13, 10089 (2021), CC BY 4.0 (opens in a new tab). MDPI (copy distributed by a co-author's institution), 2021. p. 18. doi:10.3390/su131810089
Best documented97.3 %Verified quote

9Unavoidable stops

Stops that physics or regulation impose; they set the maximum availability.

10Assumptions

  1. Label cut length, container diameter and vertical position are independent normal variables; the registration error of the cut grows with the web speed as v_web times the timing jitter of mark detection and cut.
  2. A label is nonconforming when its overlap is shorter than the minimum glue seam or when it lies outside the vertical tolerance; wrinkles, flags, glue defects and print defects are not modelled, so the quality ceiling is an upper bound. A nonconforming container is rejected (quality loss); the container and its product are not counted as yield loss.
  3. Performance: the ideal cycle is that of the maximum web speed of the declared machine; the capable process runs at the largest web speed at which the overlap keeps the declared capability margin. Machine design values (web speed, glue mass) are declared, so the rates are reported without a theoretical label.
  4. Availability: no stop is forced by physics or regulation, so availability_max = 1; manual reel splices enter only availability_scenario and oee_scenario, and the documented random failures of a labelling machine only availability_documented. No cleaning-in-place applies to a labeller, so the cleaning model is not used.
  5. The documented machine is a wet-glue labeller of returnable glass bottles in a mineral-water and soft-drink plant; its set performance and failure behaviour are used as the documented level of a labelling machine in a bottling line, not as a property of the roll-fed scenario.

11Range of validity

  • Wrap-around labels on cylindrical label panels (bottles or cans) with a glued overlap seam; pressure-sensitive, sleeve and wet-glue patch labels have other failure modes.

12Sensitivity

Elasticity: relative change of the output for a relative change of each parameter. Spearman rank correlation from the Monte Carlo draws is shown alongside.
  • Δv\Delta_vAllowed vertical displacement of the label on the panel
    elasticity 0.000Spearman ρ +0.44
  • σv\sigma_vStandard deviation of the vertical label position
    elasticity 0.000Spearman ρ -0.58
  • ono_nNominal overlap of the trailing edge over the leading edge (label design)
    elasticity 0.000Spearman ρ +0.17
  • omino_{min}Least overlap that still carries the full glue bead of the seam
    elasticity 0.000Spearman ρ -0.08
  • σt\sigma_tTiming jitter of print-mark detection and cut actuation
    elasticity 0.000Spearman ρ -0.32
  • vmaxv_{max}Maximum label-web speed of the declared labeller
    elasticity 0.000Spearman ρ -0.20
  • σD\sigma_DStandard deviation of the label-panel diameter from container to container
    elasticity 0.000Spearman ρ -0.05
  • σL,0\sigma_{L,0}Standard deviation of the cut length from the cutting mechanism alone (standstill registration)
    elasticity 0.000Spearman ρ -0.03
  • zzCapability margin of the overlap in standard deviations
    elasticity 0.000Spearman ρ -0.04
  • Output rises with the parameter
  • Output falls with the parameter

13Validation checks

A model is published only when every check passes.
  • Dimensional analysis22 outputs converted to their declared unitsPassed
  • Every cited value verified against its source5 verified, 0 failedPassed
  • No documented value beats the theoretical limitPassed
  • Ceilings in physical orderPassed
  • Fractions within 0 and 1Passed

14Causes of loss in this operation

Probability that each cause is documented as a relevant loss of a line, pooled over all segments.

15References

  1. Simulation of Energy and Media Demand of Beverage Bottling Plants by Automatic Model Generation (Bär, R. M.; Zeilmann, M.; Nophut, C.; Kleinert, J.; Beyer, K.; Voigt, T.), Sustainability 13, 10089 (2021), CC BY 4.0 (opens in a new tab). MDPI (copy distributed by a co-author's institution), 2021. p. 18. doi:10.3390/su131810089
  2. doi:10.3390/su131810089 — Bottling-plant simulation with measured set performances, MTBF and MTTR of every machine (Table A1).

Processes that use this operation