Causes of loss
Canonical causes of stoppage and inefficiency, classified into the six big losses, with their probability of presence and evidence grade.
| Cause | Loss category | Probability of presence | Expected share of lost time | Evidence grade | Studies / units |
|---|---|---|---|---|---|
| Unplanned equipment breakdownWhole line or unspecified equipment | Equipment failure (breakdowns) | 11% [6–18%] | 6.3% [3.4–10.3%] | A | 127 / 161 |
| Sterilizer piping and valve component failureSterilization (retort, UHT) | Equipment failure (breakdowns) | 6.2% [1.9–13.9%] | 3.7% [1.1–8.3%] | B | 34 / 37 |
| Packaging machine breakdownPackaging (forming, sealing, wrapping, case packing, palletizing) | Equipment failure (breakdowns) | 4.4% [1.9–8.4%] | 2.6% [1.1–4.8%] | A | 112 / 155 |
| Unspecified milling-area stoppage (mixed equipment/department code)Milling and grinding | Equipment failure (breakdowns) | 4.0% [1.2–9.2%] | 2.4% [0.7–5.6%] | B | 43 / 48 |
| Filler equipment breakdown (unspecified failure mode)Filling | Equipment failure (breakdowns) | 3.7% [1.4–7.5%] | 2.2% [0.8–4.4%] | A | 120 / 162 |
| Dryer equipment malfunction and downtimeDrying | Equipment failure (breakdowns) | 3.6% [0.9–9.2%] | 2.1% [0.5–5.4%] | C | 28 / 32 |
| Forming/blow-moulding machine breakdownForming, moulding and depositing | Equipment failure (breakdowns) | 2.3% [0.7–5.3%] | 1.3% [0.4–3.1%] | B | 76 / 96 |
| Labeling machine equipment failureLabeling and coding | Equipment failure (breakdowns) | 2.0% [0.6–4.7%] | 1.2% [0.4–2.8%] | B | 85 / 113 |
| Autoclave door/seal mechanism malfunctionSterilization (retort, UHT) | Equipment failure (breakdowns) | 1.7% [0.3–4.9%] | 1.0% [0.2–2.9%] | C | 34 / 37 |
| Bearing failureSeparation (centrifugation, filtration, membranes) | Equipment failure (breakdowns) | 1.6% [0.3–4.4%] | 0.9% [0.2–2.6%] | C | 37 / 44 |
| Mechanical, electrical or pneumatic component failureWhole line or unspecified equipment | Equipment failure (breakdowns) | 1.4% [0.5–3.2%] | 0.9% [0.3–1.9%] | B | 127 / 161 |
| Capping/sealing equipment failureCapping and seaming | Equipment failure (breakdowns) | 1.1% [0.3–3.0%] | 0.7% [0.2–1.8%] | C | 82 / 109 |
| Reactive maintenance restart delayDrying | Equipment failure (breakdowns) | 1.1% [0.2–3.6%] | 0.6% [0.1–2.0%] | D | 28 / 32 |
| Forming machine drive/chain mechanical failureForming, moulding and depositing | Equipment failure (breakdowns) | 1.1% [0.2–3.0%] | 0.6% [0.1–1.7%] | C | 76 / 96 |
| Inadequate preventive maintenance (cleaning, lubrication, tensioning)Drying | Equipment failure (breakdowns) | 1.1% [0.2–3.3%] | 0.6% [0.1–1.9%] | D | 28 / 32 |
| Basic Condition and Operating Standard Non-CompliancePackaging (forming, sealing, wrapping, case packing, palletizing) | Equipment failure (breakdowns) | 1.1% [0.3–2.7%] | 0.6% [0.2–1.6%] | C | 112 / 155 |
| Proofer equipment failureFermentation | Equipment failure (breakdowns) | 1.1% [0.2–3.2%] | 0.6% [0.1–2.0%] | D | 29 / 33 |
| Pressure sensor/transmitter calibration drift (autoclave)Sterilization (retort, UHT) | Equipment failure (breakdowns) | 1.1% [0.2–3.2%] | 0.6% [0.1–1.9%] | D | 34 / 37 |
| Sterilizer conveyor chain derailmentSterilization (retort, UHT) | Equipment failure (breakdowns) | 1.1% [0.2–3.3%] | 0.6% [0.1–1.9%] | D | 34 / 37 |
| Control instrument misalignmentSterilization (retort, UHT) | Equipment failure (breakdowns) | 1.1% [0.2–3.3%] | 0.6% [0.1–1.9%] | D | 34 / 37 |
| Homogenizer mechanical/component failure (plunger, flange, monoblock, flowmeter)Homogenization | Equipment failure (breakdowns) | 1.1% [0.2–3.4%] | 0.6% [0.1–1.9%] | D | 28 / 34 |
| Homogenizer pressure instabilityHomogenization | Equipment failure (breakdowns) | 1.1% [0.2–3.2%] | 0.6% [0.1–1.8%] | D | 28 / 34 |
| Autoclave filter clogging causing overheatingSterilization (retort, UHT) | Equipment failure (breakdowns) | 1.1% [0.2–3.1%] | 0.6% [0.1–1.8%] | D | 34 / 37 |
| Structural failure of support railSterilization (retort, UHT) | Equipment failure (breakdowns) | 1.1% [0.2–3.2%] | 0.6% [0.1–1.8%] | D | 34 / 37 |
| Unspecified fermentation equipment failureFermentation | Equipment failure (breakdowns) | 1.0% [0.2–3.3%] | 0.6% [0.1–1.9%] | D | 29 / 33 |
| Separator rotor shaft failureSeparation (centrifugation, filtration, membranes) | Equipment failure (breakdowns) | 1.0% [0.2–3.2%] | 0.6% [0.1–1.9%] | D | 37 / 44 |
| Ripple plate component failure (separator)Separation (centrifugation, filtration, membranes) | Equipment failure (breakdowns) | 1.0% [0.2–3.1%] | 0.6% [0.1–1.8%] | D | 37 / 44 |
| Tumbler shaft/body breakageMixing and blending | Equipment failure (breakdowns) | 1.0% [0.2–3.1%] | 0.6% [0.1–1.8%] | D | 31 / 40 |
| Plucking Machine Finger Wear, Misadjustment and FoulingSeparation (centrifugation, filtration, membranes) | Equipment failure (breakdowns) | 1.0% [0.2–3.1%] | 0.6% [0.1–1.8%] | D | 37 / 44 |
| Mixer equipment failureMixing and blending | Equipment failure (breakdowns) | 1.0% [0.2–3.0%] | 0.6% [0.1–1.7%] | D | 31 / 40 |
| Ingredient dosing station failure or jamMixing and blending | Equipment failure (breakdowns) | 1.0% [0.2–3.1%] | 0.6% [0.1–1.8%] | D | 31 / 40 |
| Seaming Mandrel/Roller Wear and MisalignmentCapping and seaming | Equipment failure (breakdowns) | 1.0% [0.2–2.6%] | 0.6% [0.1–1.5%] | C | 82 / 109 |
| Dough Divider Jam or Mechanical FailureForming, moulding and depositing | Equipment failure (breakdowns) | 1.0% [0.2–2.6%] | 0.6% [0.1–1.6%] | C | 76 / 96 |
| Washing/filling machine component failureContainer washing and rinsing | Equipment failure (breakdowns) | 1.0% [0.2–2.6%] | 0.6% [0.1–1.5%] | C | 80 / 102 |
| Roller arm/liner failureMilling and grinding | Equipment failure (breakdowns) | 1.0% [0.2–3.0%] | 0.6% [0.1–1.7%] | D | 43 / 48 |
| Mill center shaft drive failureMilling and grinding | Equipment failure (breakdowns) | 1.0% [0.2–2.9%] | 0.6% [0.1–1.7%] | D | 43 / 48 |
| Electrical component failureMilling and grinding | Equipment failure (breakdowns) | 1.0% [0.2–2.9%] | 0.6% [0.1–1.6%] | D | 43 / 48 |
| Fibrizer deflector malfunctionMilling and grinding | Equipment failure (breakdowns) | 1.0% [0.2–2.9%] | 0.6% [0.1–1.7%] | D | 43 / 48 |
| Grain pre-cleaning equipment failureMilling and grinding | Equipment failure (breakdowns) | 0.9% [0.2–2.9%] | 0.5% [0.1–1.7%] | D | 43 / 48 |
| Belt drive / transmission shaft failureMilling and grinding | Equipment failure (breakdowns) | 0.9% [0.2–2.7%] | 0.5% [0.1–1.6%] | D | 43 / 48 |
| Mechanical/structural breakdown maintenance (mill)Milling and grinding | Equipment failure (breakdowns) | 0.9% [0.2–2.7%] | 0.5% [0.1–1.5%] | D | 43 / 48 |
| Cane reception and preparation equipment failureMilling and grinding | Equipment failure (breakdowns) | 0.9% [0.2–2.7%] | 0.5% [0.1–1.6%] | D | 43 / 48 |
| Roller arm locker plate bolt failureMilling and grinding | Equipment failure (breakdowns) | 0.9% [0.2–2.6%] | 0.5% [0.1–1.5%] | D | 43 / 48 |
| Crown cap feed, strip and alignment malfunction at the crownerFilling | Equipment failure (breakdowns) | 0.9% [0.2–2.3%] | 0.5% [0.1–1.3%] | C | 120 / 162 |
| Inkjet printer failureLabeling and coding | Equipment failure (breakdowns) | 0.9% [0.2–2.3%] | 0.5% [0.1–1.3%] | C | 85 / 113 |
| Conveyor mechanical fault or jamConveying and accumulation | Equipment failure (breakdowns) | 0.9% [0.2–2.3%] | 0.5% [0.1–1.4%] | C | 86 / 112 |
| Oven component wear and corrosion (tray, firebox, ignition system)Baking | Equipment failure (breakdowns) | 0.8% [0.2–2.4%] | 0.5% [0.1–1.4%] | D | 60 / 73 |
| Oven equipment failureBaking | Equipment failure (breakdowns) | 0.8% [0.1–2.3%] | 0.5% [0.1–1.3%] | D | 60 / 73 |
| Pump failureWhole line or unspecified equipment | Equipment failure (breakdowns) | 0.8% [0.2–2.0%] | 0.5% [0.1–1.2%] | C | 127 / 161 |
| Ingredient weighing station fault or delayWhole line or unspecified equipment | Equipment failure (breakdowns) | 0.8% [0.2–2.0%] | 0.4% [0.1–1.1%] | C | 127 / 161 |
| Equipment down under repairWhole line or unspecified equipment | Equipment failure (breakdowns) | 0.8% [0.2–2.0%] | 0.4% [0.1–1.1%] | C | 127 / 161 |
| Automation and instrumentation failureWhole line or unspecified equipment | Equipment failure (breakdowns) | 0.8% [0.2–2.0%] | 0.4% [0.1–1.1%] | C | 127 / 161 |
| Filler inlet guide jam/failureFilling | Equipment failure (breakdowns) | 0.8% [0.2–1.9%] | 0.4% [0.1–1.1%] | C | 120 / 162 |
| Boiler breakdownUtilities (steam, compressed air, chilled water, power) | Equipment failure (breakdowns) | 0.8% [0.2–1.9%] | 0.4% [0.1–1.1%] | C | 131 / 165 |
| Electrical fault in filling/weighing equipmentFilling | Equipment failure (breakdowns) | 0.8% [0.2–1.8%] | 0.4% [0.1–1.1%] | C | 120 / 162 |
| Film handling and wrapping system failurePackaging (forming, sealing, wrapping, case packing, palletizing) | Equipment failure (breakdowns) | 0.8% [0.2–1.9%] | 0.4% [0.1–1.1%] | C | 112 / 155 |
| Tray-forming clamp/finger mechanism faultPackaging (forming, sealing, wrapping, case packing, palletizing) | Equipment failure (breakdowns) | 0.7% [0.2–1.9%] | 0.4% [0.1–1.1%] | C | 112 / 155 |
| Infeed screw/worm malfunction or jamFilling | Equipment failure (breakdowns) | 0.7% [0.2–2.0%] | 0.4% [0.1–1.1%] | C | 120 / 162 |
| Product pusher bushing wear/failureForming, moulding and depositing | Equipment failure (breakdowns) | 0.7% [0.1–2.0%] | 0.4% [0.1–1.2%] | D | 76 / 96 |
| Pellet mill mechanical failureForming, moulding and depositing | Equipment failure (breakdowns) | 0.7% [0.1–2.1%] | 0.4% [0.1–1.3%] | D | 76 / 96 |
| Gripper/clamp breakageForming, moulding and depositing | Equipment failure (breakdowns) | 0.7% [0.1–2.1%] | 0.4% [0.1–1.2%] | D | 76 / 96 |
| Aseptic carton filler subsystem failureFilling | Equipment failure (breakdowns) | 0.7% [0.2–1.8%] | 0.4% [0.1–1.0%] | C | 120 / 162 |
| Mold Safety Cam/Closure Mechanism FaultForming, moulding and depositing | Equipment failure (breakdowns) | 0.7% [0.1–2.1%] | 0.4% [0.1–1.2%] | D | 76 / 96 |
| Filler discharge jam or backupFilling | Equipment failure (breakdowns) | 0.7% [0.2–1.9%] | 0.4% [0.1–1.1%] | C | 120 / 162 |
| Filling valve malfunctionFilling | Equipment failure (breakdowns) | 0.7% [0.2–1.8%] | 0.4% [0.1–1.0%] | C | 120 / 162 |
| Bottle washer drive/gearbox failureContainer washing and rinsing | Equipment failure (breakdowns) | 0.7% [0.1–2.0%] | 0.4% [0.1–1.1%] | D | 80 / 102 |
| Compressed air leakForming, moulding and depositing | Equipment failure (breakdowns) | 0.7% [0.1–1.9%] | 0.4% [0.1–1.1%] | D | 76 / 96 |
| Deficient corrective maintenance managementCapping and seaming | Equipment failure (breakdowns) | 0.7% [0.1–2.0%] | 0.4% [0.1–1.2%] | D | 82 / 109 |
| Bottle inspection machine failureInspection and checkweighing | Equipment failure (breakdowns) | 0.7% [0.1–1.9%] | 0.4% [0.1–1.1%] | D | 79 / 101 |
| Imprinter Equipment FailureForming, moulding and depositing | Equipment failure (breakdowns) | 0.7% [0.1–2.0%] | 0.4% [0.1–1.2%] | D | 76 / 96 |
| Transfer carriage failure at tippler stationConveying and accumulation | Equipment failure (breakdowns) | 0.7% [0.1–1.9%] | 0.4% [0.1–1.1%] | D | 86 / 112 |
| Conveyor line breakdown stoppageConveying and accumulation | Equipment failure (breakdowns) | 0.7% [0.1–1.9%] | 0.4% [0.1–1.1%] | D | 86 / 112 |
| Depalletizer/Unpacker Equipment FailureConveying and accumulation | Equipment failure (breakdowns) | 0.7% [0.1–1.9%] | 0.4% [0.1–1.1%] | D | 86 / 112 |
| Expedition feed conveyor failureConveying and accumulation | Equipment failure (breakdowns) | 0.7% [0.1–2.0%] | 0.4% [0.1–1.1%] | D | 86 / 112 |
| Product leakage/spillage from bulk material conveying equipmentConveying and accumulation | Equipment failure (breakdowns) | 0.7% [0.1–1.9%] | 0.4% [0.1–1.1%] | D | 86 / 112 |
| Discharge washer mechanical/electrical failureContainer washing and rinsing | Equipment failure (breakdowns) | 0.7% [0.1–2.0%] | 0.4% [0.1–1.2%] | D | 80 / 102 |
| Capping head mechanical failureCapping and seaming | Equipment failure (breakdowns) | 0.7% [0.1–1.9%] | 0.4% [0.1–1.1%] | D | 82 / 109 |
| Discharge conveyor failureConveying and accumulation | Equipment failure (breakdowns) | 0.7% [0.1–1.9%] | 0.4% [0.1–1.1%] | D | 86 / 112 |
| Helical screw conveyor failureConveying and accumulation | Equipment failure (breakdowns) | 0.7% [0.1–1.8%] | 0.4% [0.1–1.1%] | D | 86 / 112 |
| Conveyor drive motor burnout or mechanical failureConveying and accumulation | Equipment failure (breakdowns) | 0.7% [0.1–1.8%] | 0.4% [0.1–1.1%] | D | 86 / 112 |
| Metal conveyor chain/track failureConveying and accumulation | Equipment failure (breakdowns) | 0.7% [0.1–1.8%] | 0.4% [0.1–1.0%] | D | 86 / 112 |
| Container guide rail tilting/misalignment failureSterilization (retort, UHT) | Equipment failure (breakdowns) | 0.6% [0.1–2.1%] | 0.3% [0.0–1.2%] | D | 34 / 37 |
| Thresher mechanical/electrical failureSeparation (centrifugation, filtration, membranes) | Equipment failure (breakdowns) | 0.6% [0.1–2.0%] | 0.3% [0.0–1.1%] | D | 37 / 44 |
| Wrapping machine component failurePackaging (forming, sealing, wrapping, case packing, palletizing) | Equipment failure (breakdowns) | 0.6% [0.1–1.6%] | 0.3% [0.1–0.9%] | D | 112 / 155 |
| Unplanned corrective maintenance stopPackaging (forming, sealing, wrapping, case packing, palletizing) | Equipment failure (breakdowns) | 0.6% [0.1–1.6%] | 0.3% [0.1–1.0%] | D | 112 / 155 |
| Timing belt misalignment or failurePackaging (forming, sealing, wrapping, case packing, palletizing) | Equipment failure (breakdowns) | 0.6% [0.1–1.6%] | 0.3% [0.1–0.9%] | D | 112 / 155 |
| Reverse osmosis system mechanical failureSeparation (centrifugation, filtration, membranes) | Equipment failure (breakdowns) | 0.6% [0.1–2.0%] | 0.3% [0.1–1.1%] | D | 37 / 44 |
| Control panel failureFilling | Equipment failure (breakdowns) | 0.6% [0.1–1.7%] | 0.3% [0.1–1.0%] | D | 120 / 162 |
| Inverter/VFD fault or failureMilling and grinding | Equipment failure (breakdowns) | 0.6% [0.1–1.9%] | 0.3% [0.1–1.1%] | D | 43 / 48 |
| Overheating-induced failure of sealing control components (scale, RCU, thermocouple)Packaging (forming, sealing, wrapping, case packing, palletizing) | Equipment failure (breakdowns) | 0.6% [0.1–1.6%] | 0.3% [0.1–0.9%] | D | 112 / 155 |
| Juice treatment equipment failureMilling and grinding | Equipment failure (breakdowns) | 0.6% [0.1–1.9%] | 0.3% [0.0–1.1%] | D | 43 / 48 |
| Mill motor short circuitMilling and grinding | Equipment failure (breakdowns) | 0.6% [0.1–1.9%] | 0.3% [0.0–1.1%] | D | 43 / 48 |
| Perforation blade wear, breakage or foulingPackaging (forming, sealing, wrapping, case packing, palletizing) | Equipment failure (breakdowns) | 0.6% [0.1–1.5%] | 0.3% [0.1–0.9%] | D | 112 / 155 |
| Fastener or bolt breakageFilling | Equipment failure (breakdowns) | 0.6% [0.1–1.6%] | 0.3% [0.1–0.9%] | D | 120 / 162 |
| Feed system failureMilling and grinding | Equipment failure (breakdowns) | 0.6% [0.1–1.8%] | 0.3% [0.0–1.1%] | D | 43 / 48 |
| Filler timing worm/synchronization faultFilling | Equipment failure (breakdowns) | 0.6% [0.1–1.6%] | 0.3% [0.1–0.9%] | D | 120 / 162 |
| Filling nozzle component failureFilling | Equipment failure (breakdowns) | 0.6% [0.1–1.6%] | 0.3% [0.1–0.9%] | D | 120 / 162 |
| Case packer / cartoner equipment failurePackaging (forming, sealing, wrapping, case packing, palletizing) | Equipment failure (breakdowns) | 0.6% [0.1–1.5%] | 0.3% [0.1–0.9%] | D | 112 / 155 |
| Conveyor belt system failurePackaging (forming, sealing, wrapping, case packing, palletizing) | Equipment failure (breakdowns) | 0.6% [0.1–1.6%] | 0.3% [0.1–0.9%] | D | 112 / 155 |
| Bagasse Handling Equipment FailureMilling and grinding | Equipment failure (breakdowns) | 0.6% [0.1–1.8%] | 0.3% [0.0–1.1%] | D | 43 / 48 |
| Film cutter/sealer blade failurePackaging (forming, sealing, wrapping, case packing, palletizing) | Equipment failure (breakdowns) | 0.6% [0.1–1.6%] | 0.3% [0.1–1.0%] | D | 112 / 155 |
| Mill scraper breakageMilling and grinding | Equipment failure (breakdowns) | 0.6% [0.1–1.8%] | 0.3% [0.0–1.0%] | D | 43 / 48 |
| Drive/inverter cooling fan failureMilling and grinding | Equipment failure (breakdowns) | 0.6% [0.1–1.8%] | 0.3% [0.0–1.0%] | D | 43 / 48 |
| Tray Corner Ear Flare DefectPackaging (forming, sealing, wrapping, case packing, palletizing) | Equipment failure (breakdowns) | 0.6% [0.1–1.6%] | 0.3% [0.1–0.9%] | D | 112 / 155 |
| Dosing/lobe pump jamming failureFilling | Equipment failure (breakdowns) | 0.6% [0.1–1.6%] | 0.3% [0.1–0.9%] | D | 120 / 162 |
| Dosing hose cloggingFilling | Equipment failure (breakdowns) | 0.6% [0.1–1.5%] | 0.3% [0.1–0.9%] | D | 120 / 162 |
| Storage silo equipment failure (bulk raw material)Whole line or unspecified equipment | Equipment failure (breakdowns) | 0.6% [0.1–1.6%] | 0.3% [0.1–0.9%] | D | 127 / 161 |
| Drive motor overload failure (high current draw)Milling and grinding | Equipment failure (breakdowns) | 0.6% [0.1–1.8%] | 0.3% [0.0–1.1%] | D | 43 / 48 |
| Carton Erector Equipment FailurePackaging (forming, sealing, wrapping, case packing, palletizing) | Equipment failure (breakdowns) | 0.6% [0.1–1.5%] | 0.3% [0.1–0.9%] | D | 112 / 155 |
| Air compressor failureUtilities (steam, compressed air, chilled water, power) | Equipment failure (breakdowns) | 0.6% [0.1–1.6%] | 0.3% [0.1–0.9%] | D | 131 / 165 |
| Raw material receiving equipment failureWhole line or unspecified equipment | Equipment failure (breakdowns) | 0.6% [0.1–1.5%] | 0.3% [0.1–0.9%] | D | 127 / 161 |
| Product loss from bulk material handling equipment failureWhole line or unspecified equipment | Equipment failure (breakdowns) | 0.6% [0.1–1.6%] | 0.3% [0.1–0.9%] | D | 127 / 161 |
| Steam/Power Generation Utility FailureUtilities (steam, compressed air, chilled water, power) | Equipment failure (breakdowns) | 0.6% [0.1–1.5%] | 0.3% [0.1–0.9%] | D | 131 / 165 |
| Mechanical component failureWhole line or unspecified equipment | Equipment failure (breakdowns) | 0.6% [0.1–1.5%] | 0.3% [0.1–0.9%] | D | 127 / 161 |
| Ingredient/Component Addition Equipment FailureWhole line or unspecified equipment | Equipment failure (breakdowns) | 0.6% [0.1–1.5%] | 0.3% [0.1–0.9%] | D | 127 / 161 |
| Generic steam turbine performance loss (mixed causes)Utilities (steam, compressed air, chilled water, power) | Equipment failure (breakdowns) | 0.6% [0.1–1.5%] | 0.3% [0.1–0.9%] | D | 131 / 165 |
| Weighing scale failure (electrical or mechanical)Filling | Equipment failure (breakdowns) | 0.6% [0.1–1.5%] | 0.3% [0.1–0.9%] | D | 120 / 162 |
| Vent tube bent or looseFilling | Equipment failure (breakdowns) | 0.6% [0.1–1.5%] | 0.3% [0.1–0.9%] | D | 120 / 162 |
| Sensor fouling or malfunctionWhole line or unspecified equipment | Equipment failure (breakdowns) | 0.5% [0.1–1.5%] | 0.3% [0.1–0.9%] | D | 127 / 161 |
| Minor mechanical adjustment stop on fillerFilling | Equipment failure (breakdowns) | 0.5% [0.1–1.4%] | 0.3% [0.1–0.9%] | D | 120 / 162 |
| Metal detector malfunctionFilling | Equipment failure (breakdowns) | 0.5% [0.1–1.5%] | 0.3% [0.1–0.9%] | D | 120 / 162 |
| Proofer conveyor drive failureBaking | Equipment failure (breakdowns) | 0.5% [0.1–1.8%] | 0.3% [0.0–1.0%] | D | 60 / 73 |
| Oven wheel malfunction (blow molding)Forming, moulding and depositing | Equipment failure (breakdowns) | 0.5% [0.1–1.4%] | 0.3% [0.0–0.8%] | D | 76 / 96 |
| Treated water supply failureContainer washing and rinsing | Equipment failure (breakdowns) | 0.5% [0.1–1.4%] | 0.3% [0.0–0.8%] | D | 80 / 102 |
| Conveyor belt misalignment / tracking faultConveying and accumulation | Equipment failure (breakdowns) | 0.4% [0.1–1.4%] | 0.3% [0.0–0.8%] | D | 86 / 112 |
| Label applicator jam or misfeedLabeling and coding | Equipment failure (breakdowns) | 0.4% [0.1–1.4%] | 0.3% [0.0–0.8%] | D | 85 / 113 |
| Conveyor roller fouling from dirt buildupConveying and accumulation | Equipment failure (breakdowns) | 0.4% [0.1–1.4%] | 0.3% [0.0–0.8%] | D | 86 / 112 |
| Rotary conveyor dry-run failureConveying and accumulation | Equipment failure (breakdowns) | 0.4% [0.1–1.3%] | 0.3% [0.0–0.7%] | D | 86 / 112 |
| Cutting blade failurePackaging (forming, sealing, wrapping, case packing, palletizing) | Equipment failure (breakdowns) | 0.4% [0.1–1.1%] | 0.2% [0.0–0.6%] | D | 112 / 155 |
| Nylon washer/seal wear and failureFilling | Equipment failure (breakdowns) | 0.4% [0.1–1.1%] | 0.2% [0.0–0.7%] | D | 120 / 162 |
| Filler Sealing Pad Wear/FailureFilling | Equipment failure (breakdowns) | 0.4% [0.1–1.2%] | 0.2% [0.0–0.7%] | D | 120 / 162 |
| Crown cap sorter sensor malfunctionFilling | Equipment failure (breakdowns) | 0.4% [0.1–1.1%] | 0.2% [0.0–0.6%] | D | 120 / 162 |
| Jam/blockage at coding or sealing stationFilling | Equipment failure (breakdowns) | 0.4% [0.1–1.1%] | 0.2% [0.0–0.6%] | D | 120 / 162 |
| Pneumatic Component Failure (Air Hose / Solenoid Valve)Filling | Equipment failure (breakdowns) | 0.4% [0.1–1.2%] | 0.2% [0.0–0.7%] | D | 120 / 162 |
| Filler centering bell fault/tripFilling | Equipment failure (breakdowns) | 0.4% [0.1–1.2%] | 0.2% [0.0–0.7%] | D | 120 / 162 |
| Filler support/bracket mechanical failureFilling | Equipment failure (breakdowns) | 0.4% [0.1–1.1%] | 0.2% [0.0–0.7%] | D | 120 / 162 |
| Bag loading/opening mechanism failureFilling | Equipment failure (breakdowns) | 0.4% [0.1–1.1%] | 0.2% [0.0–0.7%] | D | 120 / 162 |
| Gripper FailureFilling | Equipment failure (breakdowns) | 0.4% [0.1–1.2%] | 0.2% [0.0–0.7%] | D | 120 / 162 |
| Control system / software faultWhole line or unspecified equipment | Equipment failure (breakdowns) | 0.4% [0.1–1.1%] | 0.2% [0.0–0.6%] | D | 127 / 161 |
| Filler product bowl malfunctionFilling | Equipment failure (breakdowns) | 0.4% [0.1–1.1%] | 0.2% [0.0–0.7%] | D | 120 / 162 |
| Filling sensor failure (electrical/photoelectric)Filling | Equipment failure (breakdowns) | 0.4% [0.1–1.1%] | 0.2% [0.0–0.6%] | D | 120 / 162 |
| Star wheel / transfer wheel timing faultFilling | Equipment failure (breakdowns) | 0.4% [0.1–1.1%] | 0.2% [0.0–0.6%] | D | 120 / 162 |
| Blower malfunctionUtilities (steam, compressed air, chilled water, power) | Equipment failure (breakdowns) | 0.4% [0.1–1.1%] | 0.2% [0.0–0.6%] | D | 131 / 165 |
| Gasket wear and replacementWhole line or unspecified equipment | Equipment failure (breakdowns) | 0.4% [0.1–1.1%] | 0.2% [0.0–0.7%] | D | 127 / 161 |
| Equipment failure from deficient basic care (overheating, blockages)Whole line or unspecified equipment | Equipment failure (breakdowns) | 0.4% [0.1–1.1%] | 0.2% [0.0–0.6%] | D | 127 / 161 |
| Filler piston wear or failureFilling | Equipment failure (breakdowns) | 0.4% [0.1–1.0%] | 0.2% [0.0–0.6%] | D | 120 / 162 |
| Component wear and tearWhole line or unspecified equipment | Equipment failure (breakdowns) | 0.4% [0.1–1.1%] | 0.2% [0.0–0.6%] | D | 127 / 161 |
| Automatic lubricator (oiler) failureWhole line or unspecified equipment | Equipment failure (breakdowns) | 0.4% [0.1–1.1%] | 0.2% [0.0–0.6%] | D | 127 / 161 |
| V-belt breakage or slippageWhole line or unspecified equipment | Equipment failure (breakdowns) | 0.4% [0.1–1.1%] | 0.2% [0.0–0.6%] | D | 127 / 161 |
| Water ingress / leak from rain into equipmentWhole line or unspecified equipment | Equipment failure (breakdowns) | 0.4% [0.1–1.1%] | 0.2% [0.0–0.6%] | D | 127 / 161 |